OEM Split Electrosurgical Grounding Pads | REM Patient Return Plates | TOP-RANK
B2B contract manufacturing of dual-foil split electrosurgical grounding pads for monopolar electrosurgery. Compatible with Valleylab REM, Erbe NESSY, and standard CQM systems. Features IEC 60601-2-2 thermal rise <6.0°C, waterproof closed-cell border foam, and dual China-Vietnam supply chain routing.
Product Overview
Split electrosurgical grounding pads function as dual-channel, dynamic return transducers engineered for advanced monopolar electrosurgical units (ESUs) equipped with real-time contact interrogation circuits. Unlike non-split plates that merely ground return currents, a split plate features two electrically isolated conductor leaves configured to establish a closed-loop sensing bridge through vascularized patient tissue. When high-frequency surgical generators deliver cutting and coagulation waveforms (300 kHz to 1 MHz carrier frequencies at continuous power levels up to 300W), the dual-zone pad continuously routes RF currents back to the generator while simultaneously providing the inter-leaf bio-impedance feedback required to verify ongoing plate attachment.
Operating a dual-channel return interface under high-power surgical cutting exposes three specialized electromechanical failure mechanisms that do not occur in single-conductor grounding systems:
- Oblique Placement and Inter-Leaf Current Asymmetry: In clinical operating rooms, positioning constraints often force surgical staff to apply grounding pads diagonally across the thigh or flank relative to the surgical site. This orientation places one conductor leaf significantly closer to the active pencil than the other. The nearer leaf absorbs up to 75% of the total returning RF current flux, generating severe differential thermal dissipation between the two leaves. This thermal imbalance can trigger localized tissue damage under the overloaded leaf while leaving the overall generator power output unchanged.
- Transient Crest Flashover Across the Dielectric Isolation Trench: Modern electrosurgery employs open-circuit spray and fulguration modes that produce high-voltage pulses reaching 3.5 kV to 4.0 kV peak-to-peak. When these high-voltage bursts reflect back to the return plate, the electric field concentrates along the narrow isolation channel separating the two aluminum leaves. If the dielectric substrate contains microscopic pinholes or if condensation bridges the gap, the high-voltage field ionizes the air-gel interface, initiating a continuous surface flashover arc that short-circuits the leaves and damages the generator's sensitive Contact Quality Monitoring (CQM) interrogation stage.
- Phase-Angle Capacitive Drift Under Viscoelastic Hydrogel Desiccation: Extended laparoscopic and open resections subject the pad to multi-hour thermal loading (36°C to 38°C) from warming mattresses and surgical lamps. As the hydrogel slowly loses unbonded water, its dielectric permittivity shifts dynamically. This changes the capacitive phase angle of the interrogation signal, causing the generator's monitoring circuit to register a phantom impedance fault and lock out the surgical pencil in the middle of critical tissue dissection.
This split grounding pad platform addresses these dual-leaf operating demands through an engineered electrical layout: dual annealed aluminum leaves etched with parabolic field-relief margins that balance asymmetrical return current distributions; a high-dielectric polyester isolation barrier maintaining dielectric breakdown resistance above 4.5 kV across the central trench; and a polyacrylate-polyacrylamide copolymer hydrogel formulated to hold volume resistivity within 25 to 35 Ohm-cm at 500 kHz with stable capacitive phase characteristics across 8-hour procedures. We contract-manufacture private-label corded (universal dual-pin REM connector) and non-corded tab formats for electro-surgical device OEMs, laparoscopy supply brands, and clinical hospital networks worldwide.
Technical & Engineering Description
Contract manufacturing of split electrosurgical return pads executes inside Class 8 cleanrooms across continuous converting lines integrating high-speed foil slitting decks, continuous hydrogel extrusion units, and automated ultrasonic metal-welding modules. The fabrication flow follows five sequential engineering stages:
- Stage 1: Micro-Slit Dual-Foil Profiling & Stress Relief Contouring: Annealed electronic-grade aluminum foil (thickness 35 um, purity >99.5%) laminated to a 25 um biaxially oriented PET carrier advances through precision rotary cutting stations under closed-loop tension regulation. Micro-slitting tools excise a continuous 2.0 mm central dielectric lane to separate the web into two electrically isolated foil leaves. All interior and exterior foil corners are cut with continuous 8.0 mm parabolic curves to eliminate localized high-voltage charge accumulation. Non-contact optical vision systems scan 100% of the dielectric lane, auto-rejecting any foil section displaying slitting burrs or edge deviations beyond +/- 0.08 mm.
- Stage 2: High-Dielectric Channel Insulation & Fluid Perimeter Barrier: A 1.0 mm crosslinked closed-cell polyethylene foam web (density 65 kg/m3) is pre-coated on its skin-facing side with a medical acrylic pressure-sensitive adhesive. Rotary punch tooling removes the central window while preserving an internal 12.0 mm outer adhesive perimeter. This carrier web is aligned and laminated over the split aluminum foil, completely framing the active elements and sealing the central 2.0 mm isolation gap against lateral moisture migration, ensuring that the channel maintains a dielectric breakdown threshold >4.5 kV.
- Stage 3: Copolymer Hydrogel Extrusion & Vacuum Lamination: An extruded 0.95 mm slab of crosslinked polyacrylate-polyacrylamide copolymer hydrogel is applied directly across the active foil elements. The hydrogel is formulated with 38% vegetable glycerol, a 2.5% electrolyte reserve, and high molecular-weight crosslinkers, balancing a volume resistivity below 35 Ohm-cm at 500 kHz with high specific heat capacity. Calibrated vacuum compaction rolls eliminate interfacial micro-voids between the hydrogel and foil, creating an isotropic conduction interface that facilitates rapid lateral heat dissipation under sudden current surges.
- Stage 4: Automated Ultrasonic Foil-to-Copper Atomic Bonding: For corded configurations, the distal ends of a 3.0 m twisted-pair copper cable (2x22 AWG, tinned copper strands encased in a flexible medical PVC jacket) are stripped and positioned over the terminal tabs of the two independent aluminum leaves. An automated 35 kHz ultrasonic welder delivers calibrated acoustic energy and clamping force, breaking the surface aluminum oxide film to form a true atomic intermetallic bond with contact resistance below 0.015 Ohms. A molded polyolefin strain-relief shell is heat-formed over the junction, delivering tensile retention >45N. The opposing cable end terminates in an integrally molded dual-pin REM connector compliant with international ESU socket standards.
- Stage 5: Inline Dielectric Proof Testing & Nitrogen Barrier Pouching: Finished pads are cut by hardened rotary dies featuring 10.0 mm outer corner radiuses. Every finished unit passes an automated quality station: a 3,000V high-voltage impulse test verifies the dielectric integrity of the central split gap, followed by a dual-channel resistance measurement to ensure that dry inter-leaf impedance matches factory calibration limits. Qualified units mount on 75 um fluorosilicone PET release cards, pass into horizontal flow-wrappers, and are sealed inside multi-layer PET/AL/PE foil pouches with nitrogen gas flushing. The standard contract manufacturing MOQ is 10,000 pouches.
Key Features
-
Differential Dual-Foil REM Impedance Sensing (Interrogation Loop Halting Pad-Peel RF Burns)
The catastrophic safety hazard in monopolar electrosurgery is patient plate partial detachment: if a traditional single-foil pad peels half-off, the return surface area halves, causing RF current density to quadruple and producing third-degree burns within seconds. Our split grounding pad resolves this hazard by establishing an active interrogation circuit compatible with Contact Quality Monitoring (CQM, Valleylab REM, Erbe NESSY) systems: The pad surface is divided down its longitudinal axis into two symmetrical, electrically isolated aluminum foils separated by a 2.0 mm dielectric gap. When adhered to the patient, the biological tissue beneath the pad completes an alternating electrical interrogation loop. The ESU generator injects a continuous, low-amplitude high-frequency interrogation signal (typically 20 kHz to 140 kHz, current <1.0 mA) across the two terminals. Current passes from Leaf A through the conductive hydrogel, traverses the epidermal and subcutaneous tissue layers, and returns through Leaf B: Interrogation Impedance = Tissue Impedance + Contact Boundary Resistance. On healthy human skin, the total measured resistance sits between 15 and 80 Ohms. If the pad begins to detach from patient movement, surgical table manipulation, or drying, the active skin contact area shrinks. Interfacial resistance rises proportionally. The moment measured resistance exceeds 135 Ohms-or if dynamic resistance shifts upward by more than 40% from the established baseline-the ESU generator's comparator circuit trips within 20 milliseconds. The system triggers an audible and visual alarm and terminates RF power delivery to the surgeon's pencil, stopping thermal energy output before current density can escalate to necrotic burn levels.
-
Leading-Edge Equipotential Gradient Design (Suppressing RF Perimeter Crowding & Capping Thermal Rise <4.5°C per IEC 60601-2-2)
When monopolar electrosurgical current enters biological tissue from the active pencil tip, it spreads in three dimensions through the body before converging on the grounding pad. Due to the rapid frequency of the carrier wave (300 kHz to 1 MHz), current behaves according to transmission-line and dielectric field principles. The returning current follows the path of least capacitive impedance, creating severe "leading-edge crowding." Instead of spreading across the 132 cm2 conductor, up to 70% of the total RF current rushes into the narrow 10 mm margin of the pad closest to the surgical incision. If the pad utilizes a standard rectangular foil with sharp 90-degree corners and high-impedance gel, localized current density at this leading edge exceeds 2.5 mA/mm2. The skin undergoes severe Joule heating: Local Temperature Rise is proportional to the square of Local Current Density multiplied by Resistance and Duration. This concentrated heating causes thermal blisters and burns under the leading margin, even though the trailing half of the pad remains room temperature. Our platform resolves this thermal bottleneck through an integrated equipotential gradient geometry:
1.Wide-Radius Leading Contours: All four corners of the conductive aluminum leaves are stamped with broad 8.0 mm radiused curves. This eliminates sharp corner points that serve as capacitive charge collectors, spreading the entry electric field smoothly across a broad parabolic boundary.
2.Isotropic Low-Impedance Gel Matrix: The 0.95 mm crosslinked hydrogel is compounded with an optimized 2.5% pharmaceutical sodium chloride electrolyte phase and a high bound-water ratio, driving bulk high-frequency volume resistivity below 40 Ohm-cm at 500 kHz. The gel acts as an isotropic buffer layer: when the returning RF field strikes the leading edge, the low-impedance matrix allows charge to disperse across the foil face before crossing the dermal barrier. In standardized laboratory verification complying with IEC 60601-2-2 clause 201.15.101.5 (applying continuous 700 mA RF current for 60 seconds across human volunteers), the peak dermal temperature rise beneath the leading edge remains clamped below 4.5°C. This is well below the strict 6.0°C regulatory limit, providing clinical safety margins during prolonged, high-power electrosurgical procedures.
-
Hydrophobic Closed-Cell Border Gasket (Complete Seal Against Surgical Fluid Infiltration & False REM Bridging)
In open abdominal, gynecological, and orthopedic surgeries, large volumes of fluid are deployed for irrigation, tissue debridement, and disinfection. These conductive saline solutions flow across the patient's skin and pool beneath the torso and legs. Standard grounding pads with narrow or breathable borders suffer fluid intrusion within 30 to 60 minutes:
1.Liquid capillary action draws saline into the pad margins, dissolving the pressure-sensitive adhesive and lifting the foam border.
2.Saline penetrates the active contact area, reaching the 2.0 mm dielectric isolation channel separating the two aluminum foil leaves.
3.Because sterile saline and prep solutions have high electrical conductivity, the fluid bridges the isolation lane. This creates an external direct-short circuit between Leaf A and Leaf B. When this occurs, the ESU generator's CQM system interrogates the pad and registers an artificially low resistance (typically 20 to 30 Ohms). The console displays a green "safe" status, even if the hydrogel beneath has detached by 70% from fluid flooding. The surgical team continues cutting under a false sense of security, while the remaining skin contact area is subjected to extreme current density, causing catastrophic patient burns. We resolve this clinical risk by surrounding the active dual foils with an engineered fluid-tight border assembly:
4.High-Density Crosslinked Foam: The outer carrier utilizes a 1.0 mm thick closed-cell polyethylene foam (density 65 kg/m3). The crosslinked polyolefin cell walls are impervious to water, alcohol, and surgical scrub detergents.
5.12.0 mm Wide Adhesive Barrier: The foam carrier extends 12.0 mm beyond the hydrogel edge on all sides. The underside is coated with a crosslinked acrylic pressure-sensitive adhesive at a coat weight of 50 g/m2, formulated to maintain skin adhesion (>4.2N/25mm) even in moist environments. In liquid submersion and fluid-channeling testing complying with operating room splash scenarios, the hydrophobic border forms an unbroken gasket that prevents fluid from crossing the hydrogel perimeter. The 2.0 mm dielectric isolation channel remains dry, preventing false CQM bridging and ensuring that the ESU generator alarms reliably if the pad experiences true mechanical detachment.
Applications
High-Power General & Orthopedic Monopolar Surgery
Deployed across hospital operating suites for high-energy procedures, including total hip/knee arthroplasty, liver resections, spinal fusions, and open bariatric surgeries; 210x125 mm adult split pads safely dissipate continuous 500 kHz to 1 MHz monopolar pulses at power settings exceeding 200W, preventing leading-edge thermal burns during long surgical sessions.
Fluid-Intensive Laparoscopic & Endoscopic Electrosurgery
Sourced by surgical centers conducting laparoscopic cholecystectomies, hysteroscopies, and urological TURP procedures where saline and irrigants pool under the patient; the 12.0 mm closed-cell foam border blocks fluid infiltration, protecting the dielectric split from short-circuiting and eliminating false REM readings.
Pediatric Surgery Suites & Specialty Inpatient Units
Utilized in pediatric surgery suites for patients weighing between 5 kg and 15 kg; custom 150x100 mm split return pads feature an active area of 65 cm² paired with an ultra-gentle, skin-safe hydrogel that prevents epidermal stripping upon removal while providing calibrated REM compatibility with pediatric electrosurgical generator modes.
OEM & Private Label
-
Corded vs. Non-Corded, Cable Pinouts & Packaging Customization : We offer comprehensive contract manufacturing options for private-label surgical device companies and hospital supply networks:
• Configuration Modalities: Pre-corded product lines featuring 3.0 m or 5.0 m integrated twisted-pair copper cables with molded standard 2-pin universal REM connectors; or non-corded tab-style pads compatible with reusable hospital spring-clamp connecting cables (Valleylab and universal hospital clamp styles).
• Footprint Sizing: Standard Adult Split (210x125 mm, active area >132 cm²); Adult Extra-Large (220x135 mm for bariatric protocols); and Pediatric Split (150x100 mm, active area >65 cm² for patients under 15 kg).
• Backing Foam Profiles: Standard 1.0 mm crosslinked closed-cell PE foam (white, waterproof); optional breathable medical non-woven carrier with integrated hydrophobic perimeter border.
• Sterility & Packaging Profiles: Available non-sterile in bulk clinical pouches (5 pads per resealable pouch, 100 pads per carton) or sterile ethylene oxide (EtO) processed individual peel pouches for direct operating room sterile field delivery; multi-color gravure packaging with serialized UDI barcodes, device IFU alignment illustrations, and custom corporate branding.
-
Two-Center Supply Chain Mechanics : High-purity aluminum foil laser/rotary slitting, specialized high-frequency conductive hydrogel synthesis, non-woven/PE foam medical adhesive coating, and automated cable ultrasonic bonding execute natively inside our primary China facility (ISO 13485:2016 and FDA registered). High-speed rotary die-cutting, automated online RF impedance scanning, multi-layer foil pouch hermetic heat-sealing, cleanroom cartoning, and palletized ocean container export route through our Vietnam hub, shielding international B2B buyers from regional medical device tariffs and Section 301 duties.
Certifications
-
IEC 60601-2-2 Thermal Rise Performance Certification : Master production lots undergo testing in accredited independent testing laboratories confirming strict compliance with IEC 60601-2-2 clause 201.15.101.5 (High-Frequency Surgical Equipment - Safety of Patient Return Electrodes). In continuous testing delivering 700 mA RF current for 60 seconds across human subjects, peak dermal temperature rise remains below 4.5°C (well under the 6.0°C maximum limit). Pad adhesive peel tack conforms to ANSI/AAMI HF18 electrosurgical dispersive electrode guidelines.
-
ISO 10993 Comprehensive Dermal Biocompatibility : Master production lots undergo testing in accredited independent testing laboratories confirming strict compliance with ISO 10993-5 (In Vitro Cytotoxicity Grade 0), ISO 10993-10 (Skin Sensitization: 0% allergic response in guinea pig maximization tests), and ISO 10993-23 (Primary Dermal Irritation Index = 0.0). The complete electrode assembly is certified 100% natural rubber latex-free, phthalate-free, non-toxic, and non-sensitizing over prolonged surgical procedures.
-
Electrical Safety & Mechanical Retention Verification : Product lines satisfy FDA 21 CFR 878.4400 requirements for electrosurgical devices and IEC 60601-1 Type BF/CF electrical safety standards. Routine lot sampling confirms that pre-corded leadwires withstand axial pull forces exceeding 45N without electrical discontinuity, and the 2.0 mm dielectric isolation split withstands high-voltage testing at 1,500V without dielectric breakdown or flashover.
-
MDSAP & ISO 13485 Manufacturing System Controls : Continuous coating decks, automated slitting bays, and cleanroom pouch packaging run strictly under certified ISO 13485:2016 and MDSAP regulatory frameworks (covering US FDA 21 CFR 820, Health Canada, TGA Australia). Unbroken electronic Device History Records (DHR) capture aluminum web slitting tolerances, hydrogel volume resistivity, temperature-rise verification curves, and cable tensile pull-force data across every production lot.
Technical FAQ
Q: How does the split geometry and dielectric channel width prevent false REM triggering while maintaining capacitive balance?
A: In split dispersive electrodes, the physical dimensions of the dielectric isolation channel determine the electromechanical balance between high-frequency RF current return and low-frequency REM contact quality interrogation: • The Physics of Channel Width Optimization: The central channel separates the aluminum foil into two independent electrical planes (Leaf A and Leaf B). This channel must simultaneously fulfill two contradictory electrical demands: 1.Suppressing High-Voltage RF Breakdown: During monopolar coagulation, peak radiofrequency voltages can exceed 1,000V. If the dielectric split is too narrow (e.g., under 1.0 mm), the intense electric field across the gap ionizes ambient air and moisture, causing dielectric breakdown, arcing, and localized thermal burns across the center of the pad. 2.Maintaining Accurate REM Interrogation Impedance: The ESU's Contact Quality Monitoring (CQM) circuit injects a low-amplitude interrogation signal (20 kHz to 140 kHz) across the two leaves. The interrogation current passes from Leaf A, through the hydrogel, into the subcutaneous tissue, and returns through Leaf B. If the dielectric split is too wide (e.g., over 4.0 mm), the physical distance between the two conductors introduces excessive lateral biological path resistance. The baseline resistance climbs dangerously close to the ESU's 135-Ohm trip threshold on patients with dry or calloused skin, triggering false-positive detachment alarms and halting surgery unnecessarily. • Our Engineering Solution: We resolve this compromise by engineering an exact 2.0 mm (+/- 0.2 mm) dielectric channel stamped via optical servo-guided rotary dies. The 2.0 mm spacing provides a dielectric breakdown safety margin exceeding 1,500V, eliminating micro-arcing between leaves during full-power coagulation bursts. Simultaneously, the lateral biological path length is kept short enough that baseline REM interrogation resistance on human tissue stabilizes between 25 and 65 Ohms-comfortably inside the ESU's 15- to 135-Ohm safe monitoring window. The geometry balances uninterrupted high-frequency energy evacuation with sensitive, fault-free contact quality monitoring.
Q: Why does the leading-edge effect occur during 300 kHz to 1 MHz monopolar discharge, and how does the dispersive hydrogel formulation hold temperature rise below 4.5°C under a 700 mA load?
A: Interfacial burns under electrosurgical dispersive pads are governed by the electrical field behavior of radiofrequency alternating currents interacting with biological impedances: • The Mechanism of Leading-Edge Current Crowding: Monopolar electrosurgery relies on alternating carrier frequencies between 300 kHz and 1 MHz. Unlike direct current, high-frequency RF current flows according to capacitive admittance: Capacitive Admittance is proportional to Frequency multiplied by Interfacial Capacitance. As RF energy enters the patient's body from the surgical pencil, it traverses heterogeneous tissue layers (muscle, adipose tissue, fascia). When this current approaches the grounding pad, charge takes the path of least capacitive impedance. The returning current converges aggressively on the nearest edge of the pad-the leading edge facing the operative field. Up to 70% of the entire RF current crowds into the first 10 mm to 15 mm margin of the conductive foil. In poorly formulated pads, localized current density spikes above 2.5 mA/mm2. The skin directly beneath this leading edge experiences intense Joule heating (P = I² • R), causing peak temperatures to surge past the 45°C tissue damage threshold in less than 30 seconds, while the trailing half of the pad remains completely cold. • Our Thermally Buffered Hydrogel Engineering: We prevent leading-edge thermal spikes and comply with the sub-6°C requirements of IEC 60601-2-2 through three formulation controls: 1.Optimized High-Frequency Ionic Conductivity: The polyacrylate hydrogel is synthesized with a 2.5% pharmaceutical sodium chloride electrolyte phase and a high bound-water ratio (>45%), driving bulk volume resistivity below 40 Ohm-cm at 500 kHz. When RF current strikes the leading edge, the low internal bulk impedance allows charge to redistribute laterally across the foil conductor plane before penetrating the skin. 2. High Heat Capacity Buffer: The inclusion of a 38% high-purity vegetable glycerol humectant phase elevates the specific heat capacity of the hydrogel slab. The 0.95 mm thick gel layer acts as a thermal heat sink, absorbing localized Joule energy and buffering transdermal heat transfer. 3.Blunted Corner Geometry: Broad 8.0 mm radiused corners on both aluminum leaves eliminate sharp conductive points, preventing peripheral field convergence. In standardized type testing complying with IEC 60601-2-2 clause 201.15.101.5 (applying continuous 700 mA RF current for 60 seconds across human subjects), peak dermal temperature rise beneath the leading edge remains clamped below 4.5°C. The temperature profile demonstrates balanced thermal dissipation across the entire active footprint, preventing patient contact burns during extended high-current monopolar procedures.
Electrosurgical device manufacturers, operating room supply chain managers, and surgical consumable procurement directors can request official Certificates of Analysis (COA), IEC 60601-2-2 clause 201.15.101.5 thermal rise test logs, ISO 10993 dermal biocompatibility dossiers, and unbranded evaluation sample packs (including corded 3.0 m dual-pin REM and non-corded tab formats for adult and pediatric applications).
👉 [Request Split Electrosurgical Grounding Pad Evaluation Packs]
Hot Tags: split electrosurgical grounding pads, China split electrosurgical grounding pads manufacturers, suppliers, factory, electrical grounding pad, electrocautery pads, Electrosurgical Grounding Pads, electrosurgical pad, Grounding Pad, surgical grounding pad
Specifications
| Analytical Parameter | Engineering Baseline | Testing Standard |
| Footprint Formats | Adult: 210x125 mm (Total: ~260 cm²); Pediatric: 150x100 mm | Clinical surgical standards |
| Active Conductive Area | Adult: > 132 cm² (66 cm² per split leaf); Pediatric: > 65 cm² | ANSI/AAMI HF18 |
| Conductive Substrate | 35 um High-Purity Laminated Aluminum Foil (Double Leaf) | Tensile & conductivity |
| Dielectric Split Width | 2.0 mm (+/- 0.2 mm) Linear Dielectric Isolation Channel | High-voltage breakdown |
| Peripheral Waterproof Border | 12.0 mm Closed-Cell Crosslinked PE Foam (Caliper: 1.0 mm) | Fluid barrier test |
| Electrolyte Hydrogel | Isotropic Polyacrylate Solid Matrix (Thickness: 0.90 to 1.00 mm) | High hydration |
| High-Frequency Resistivity | < 40.0 Ohm-cm at 500 kHz (Typical batch: 22 to 30 Ohm-cm) | Four-electrode RF cell |
| REM Interrogation Range | Contact Impedance: 15 to 80 Ohms on Human Skin | ESU compatibility |
| Thermal Rise Compliance | Maximum Temp Rise < 4.5°C under 700 mA RF for 60s | IEC 60601-2-2 clause 201.15.101.5 |
| Skin Adhesion Peel Tack | 4.2N to 5.5N / 25 mm on Polished Stainless Steel | ASTM D3330 |
| Cable Integrity (Corded) | 3.0 m (or 5.0 m) Twisted-Pair High-Flex Copper Leadwire | IEC 60601-1 |
| Plug Pinout Standards | Molded Universal 2-Pin REM Plug (Center Pitch: 10.0 mm) | Molded ABS/PVC |
| Non-Corded Tab Caliper | Standard 25.4 mm (1.0 inch) Tab with Alignment Notches | Spring-clip retention |
| Barrier Shelf-Life | 36 Months sealed in Multi-Layer Foil Pouches at 15°C–30°C | Accelerated aging |
| Contract Manufacturing MOQ | 10,000 Pouches (Packed 1 pc/pouch or 5 pcs/pouch) | Factory direct |