Solid Ultrasound Coupling Pad

Solid Ultrasound Coupling Pad
Details:
Solid Ultrasound Coupling Pads operate as pre-formed, thin-profile (2.0 mm to 3.0 mm) elastomeric hydrogel transmission discs engineered to replace bulk liquid couplants during high-precision diagnostic and interventional ultrasound procedures

The industrial manufacture of Solid Ultrasound Coupling Pads operates inside ISO 13485-certified Class 8 cleanrooms across closed-loop chemical compounding and precision continuous-cast production platforms operating under US FDA 21 CFR 820 design controls.

The baseline contract manufacturing MOQ is 10,000 units.
Send Inquiry
Download
Description
Technical Parameters
 

OEM Solid Ultrasound Coupling Pad | Sterile Acoustic Couplant | TOP-RANK

 

 

B2B contract manufacturing of thin-profile solid ultrasound coupling pads for sterile vascular access, POCUS, and shear-wave elastography (SWE). Features acoustic velocity 1540 m/s, thickness 2.0-3.0 mm, zero-liquid pathogen transmission, and turnkey OEM packaging.

 

Product Overview

 

Solid Ultrasound Coupling Pads operate as pre-formed, thin-profile (2.0 mm to 3.0 mm) elastomeric hydrogel transmission discs engineered to replace bulk liquid couplants during high-precision diagnostic and interventional ultrasound procedures. Designed for point-of-care ultrasound (POCUS), ultrasound-guided vascular catheterization, regional anesthesia nerve blocks, and quantitative shear-wave elastography (SWE), these solid pads couple diagnostic transducers directly to human skin without fluid migration. Formulated with an exact acoustic velocity of 1540 m/s and an acoustic impedance of 1.54 MRayls, the pad provides an isotropic, non-attenuating acoustic conduit. Because the material exists entirely in an elastic solid phase, it eliminates the mess, droplet splatter, and cleaning overhead of liquid gels while providing a sterile, pathogen-free barrier over breached skin and needle entry sites.

Deploying conventional bottled liquid ultrasound gels during interventional and bedside sterile ultrasound creates three distinct clinical, physical, and acoustic failure modes:

  • Nosocomial Biofilm Seeding and Bloodstream Infections in Vascular Catheterization: Multi-use squeeze bottles of liquid ultrasound gel are recognized vectors for hospital-acquired outbreaks of multidrug-resistant pathogens (Burkholderia cepacia, Pseudomonas aeruginosa, Klebsiella pneumoniae). During ultrasound-guided central venous line (CVC) or arterial line insertions, clinicians apply gel over or adjacent to the sterile drape. Liquid gel frequently seeps into the puncture tract under transducer movement, carrying viable bacteria directly into the bloodstream or fascial planes, leading to catheter-related bloodstream infections (CRBSI).
  • Kinematic Probe Slippage and Needle-Tip Visual Loss Under Liquid Lubrication: Precise ultrasound-guided needle tracking requires micro-positioning stability. Liquid ultrasound gel behaves as a low-viscosity hydrodynamic lubricant. Under probe manipulation, the transducer slips sideways across the skin, losing alignment with the 0.5 mm needle tip. To prevent slip, operators push down firmly, collapsing target veins and increasing the risk of through-and-through posterior wall arterial puncture. Furthermore, probe tilt draws air micro-bubbles under the lens, generating acoustic shadow dropouts.
  • Transverse Shear-Wave Damping in Quantitative Elastography (SWE): In advanced shear-wave elastography and acoustic radiation force impulse (ARFI) imaging, the ultrasound probe tracks micro-meter lateral displacements to calculate tissue stiffness (Young's modulus in kPa). Liquid gel forms an unconstrained fluid boundary layer that dissipates transverse shear energy. The mathematical tracking algorithms register boundary shear slip rather than true parenchymal displacement, generating false tissue stiffness measurements in liver fibrosis staging and musculoskeletal assessments.

The Solid Ultrasound Coupling Pad manufacturing platform resolves these interventional risks through material engineering: a crosslinked polyacrylamide-co-polyacrylate solid hydrogel matrix synthesized with zero unbound liquid phase, providing a sterile acoustic transmission barrier that does not harbor bacterial biofilms or migrate into open puncture wounds; an engineered surface kinematic coefficient of friction that stabilizes probe positioning without sliding; and an isotropic elastic shear network that transmits transverse shear waves with minimal boundary damping (<0.06 dB/cm-MHz). We contract-manufacture private-label solid coupling pads in gamma-sterilized peel-pouches and clinical multi-packs for ultrasound transducer OEMs, vascular access kit assemblers, and interventional radiology distributors globally.

 

Technical & Engineering Description

 

The industrial manufacture of Solid Ultrasound Coupling Pads operates inside ISO 13485-certified Class 8 cleanrooms across closed-loop chemical compounding and precision continuous-cast production platforms operating under US FDA 21 CFR 820 design controls. Production proceeds across five coordinated engineering stages:

  • Stage 1: Multi-Pass EDI Water Polishing & Stoichiometric Acoustic Monomer Compounding: Pharmaceutical raw process water passes through dual-pass reverse osmosis (RO) units coupled with continuous electrodeionization (EDI), suppressing input electrical conductivity below 0.08 uS/cm. The deionized water charges into jacketed 316L stainless steel reaction vessels. Analytical-grade acrylamide, acrylic acid, hydrophilic polyol plasticizers, and bi-functional covalent crosslinkers (N,N'-methylenebisacrylamide) are charged in exact stoichiometric proportions. The inorganic salt buffer is titrated to calibrate the acoustic propagation velocity of the bulk solution to an exact 1540 m/s (+/- 8 m/s) with a baseline acoustic impedance of 1.54 MRayls.
  • Stage 2: High-Vacuum Centrifugal Multi-Axis Degassing: Entrapped micro-bubbles in ultrasound coupling media scatter acoustic wave packets and cast reverberation shadows. The liquid monomer blend feeds into industrial vacuum centrifugal degassing chambers drawn down to an internal negative pressure of -0.098 MPa under dual-axis planetary rotation (2,000 RPM). High centrifugal force and vacuum pull dissolved oxygen and micro-air voids out of the matrix, continuing until dissolved oxygen measures below 0.15 ppm and automated laser particle counters confirm an internal bubble count of zero.
  • Stage 3: High-Precision Slot-Die Casting & In-Line Nitrogen UV Photopolymerization: The degassed monomer feeds through automated positive-displacement gear pumps into a multi-port slot-die extrusion manifold. The liquid is cast as a continuous, calibrated sheet (thickness: 2.0 mm, 2.5 mm, or 3.0 mm +/- 0.1 mm) directly onto a moving 75 um fluorosilicone-treated PET release liner. The web immediately indexes into an enclosed, nitrogen-purged polymerization tunnel (<30 ppm O2). Multi-wavelength UV LED irradiators trigger uniform free-radical crosslinking across 60 seconds, converting the liquid film into an elastic solid hydrogel slab with a monomer conversion rate exceeding 99.8%.
  • Stage 4: Rotary Semi-Rotary Die-Cutting & Optical Acoustic Verification: The polymerized hydrogel web laminates against a protective top release film before feeding into automated tungsten-carbide rotary die-cutting cylinders. The cylinders kiss-cut precision geometric formats (disks Dia 40 mm to Dia 80 mm, or rectangles for linear arrays) without edge feathering or burrs. Every master production roll undergoes 100% automated optical inspection alongside acoustic quality assurance: a 10 MHz immersion acoustic transducer measures longitudinal sound speed (1540 m/s), validates acoustic impedance (1.54 MRayls), and confirms acoustic attenuation below 0.06 dB/cm-MHz across high frequencies.
  • Stage 5: Cleanroom Blister Sealing & Terminal Gamma Sterilization Routing: Cut coupling pads are transferred by automated pick-and-place arms into medical-grade thermoformed PETG blister trays. Trays are sealed under 0.45 MPa platen pressure with medical-grade breathable Tyvek peel-lids (or aluminum barrier foil for non-sterile lines). For sterile interventional lines, sealed blister packs route through validated gamma radiation sterilization (conforming to ISO 11137-2 achieving a Sterility Assurance Level of 10^-6). Finished units are boxed into clinical dispenser cartons labeled with serialized GS1/UDI barcodes. The baseline contract manufacturing MOQ is 10,000 units.

 

Key Features

 

  1. Zero-Fluid Biofilm Isolation & Sterile Field Containment (Halting Nosocomial Bloodstream Seeding in Ultrasound-Guided Vascular Catheterization) 

    Ultrasound-guided central venous catheterization (CVC), PICC line placement, and arterial line cannulation are critical interventions in intensive care units (ICU) and operating theaters. In these sterile procedures, conventional liquid ultrasound gel creates a severe vector for hospital-acquired infections (HAIs):

    1. The Fluid Contamination Pathway: Multiple independent clinical studies and CDC safety alerts identify multi-use squeeze bottles of ultrasound gel as sources of bacterial contamination (Burkholderia cepacia, Serratia marcescens). When a physician applies liquid gel to locate an internal jugular or femoral vein, the transducer motion spreads the liquid across the surgical field.

    2. Needle Tract Implantation: When the vascular needle punches through the skin, the fluid gel clings to the needle shaft via surface tension. The liquid is drawn directly into the subcutaneous tissue and the venous lumen. Bacteria suspended in the gel colonize the external surface of the indwelling catheter, forming an antibiotic-resistant biofilm that seeds recurrent catheter-related bloodstream infections (CRBSI).

    3. Difficult Wound Cleanliness: Post-procedure, liquid gel trapped around the insertion site degrades the adhesive seal of transparent dressings (like Tegaderm), causing dressing lift and secondary contamination. Our Solid Ultrasound Coupling Pad eliminates puncture-tract infection vectors through solid-state cohesion:

    4. Zero Unbound Liquid Phase: The pad is synthesized as a continuous, crosslinked elastomeric polymer slab holding zero mobile fluid. There is no free liquid to run, splatter, or wick into open needle wounds.

    5. Physical Acoustic Barrier: The sterile pad (SAL 10^-6 verified via ISO 11137) is placed over the targeted vascular site. The physician visualizes the vein through the pad, and the puncture needle passes directly through the elastomeric pad into the skin.

    6. Zero Foreign-Body Implantation: Because the hydrogel has high internal cohesive strength (tensile strength >1.2 MPa), needle penetration causes zero coring or gel fragmentation. The needle shaft enters the skin completely clean and dry, eliminating bacterial inoculation and leaving the surrounding skin dry for immediate, secure dressing adhesion.

     

  2. Dynamic Kinematic Friction Stabilization (Non-Slip Probe Traction for Millimeter-Precise Needle-Tip Tracking in Interventional POCUS) 

    In critical vascular access and nerve blocks, losing acoustic visual alignment with the needle tip is the primary cause of clinical complications (such as inadvertent arterial puncture, hematoma formation, or pneumothorax):

    1. The Fluid Slip Hazard: Standard liquid ultrasound gel acts as a hydrodynamic boundary lubricant. When a physician holds the ultrasound probe with one hand while advancing a needle with the other:

    2. Transducer Hydroplaning: The probe easily slides, rotates, or slips out of the millimeter-thin acoustic scanning plane under slight hand pressure. The hyperechoic needle tip disappears from the ultrasound screen.

    3. Vein Collapse from Downward Over-Compression: To stop the probe from sliding across slippery liquid gel, operators unconsciously press down on the probe with excessive normal force. This downward pressure compresses and collapses superficial, low-pressure veins (such as pediatric internal jugular or basilic veins). The target lumen disappears, forcing repeated needle passes and increasing tissue trauma. Our Solid Ultrasound Coupling Pad stabilizes probe kinematics through calibrated surface friction:

    4. Engineered Coefficient of Friction: The hydrogel surface is cured to deliver a kinematic dynamic coefficient of friction (u) between 0.45 and 0.65 against typical silicone and polyether probe acoustic lenses.

    5. Tactile Hand-Tracking Stabilization: When the probe seats against the solid pad, the elastic surface provides firm lateral traction. The probe resists involuntary angular drift, rotation, or hydroplaning. The physician can float the probe lightly over the vessel without pushing down, preserving target venous lumen diameter for easy cannulation.

    6. Millimeter-Precise In-Plane Guidance: The stable mechanical platform ensures that the needle path remains locked inside the longitudinal sound beam, allowing the physician to track the advancing needle tip millimeter by millimeter from skin entry directly into the vascular target.

     

  3. Transverse Shear-Wave Boundary Propagation (Sub-0.06 dB/cm-MHz Transmission for Quantitative Elastography and ARFI Push-Pulses) 

    Quantitative ultrasound elastography-including Shear-Wave Elastography (SWE), Acoustic Radiation Force Impulse (ARFI), and transient elastography-evaluates soft tissue pathology by tracking the propagation speed of transverse shear waves:

    1. The Fluid Boundary Failure of Liquid Gels: Conventional liquid ultrasound gels transmit longitudinal compressional sound waves efficiently; however, liquids have zero shear modulus (G = 0). When a modern ultrasound transducer emits an acoustic radiation push-pulse to generate a transverse shear wave:

    2. Shear Energy Dissipation: The shear wave attempts to propagate across the tissue-probe boundary. A liquid gel layer forms an unconstrained fluid boundary condition that absorbs and dampens lateral shear displacements.

    3. Measurement Artifacts: The instrument's tracking algorithms suffer boundary slip, resulting in erratic shear-wave speed calculations and distorted tissue stiffness outputs (producing false-positive liver cirrhosis staging or inaccurate breast tumor grading). Our Solid Ultrasound Coupling Pad enables accurate elastography through solid-phase shear transmission:

    4. Matched Viscoelastic Shear Modulus: The crosslinked polyacrylamide-polyacrylate interpenetrating polymer network is cured to establish an elastic Young's modulus ($E$) between 12 and 18 kPa, with a shear loss tangent below 0.04.

    5. Unbroken Shear Boundary Continuity: Because the pad is an elastic solid, it supports the transmission of transverse shear displacements across the probe interface without liquid boundary slip. Acoustic radiation force push-pulses generate clean shear-wave fronts that propagate through the pad into biological tissue.

    6. Broadband Acoustic Transparency: Across high imaging frequencies (2.0 MHz to 18.0 MHz), acoustic attenuation is held strictly below 0.06 dB/cm-MHz. In phantom validation trials comparing liver tissue models, ultrasound systems using our solid coupling pads matched reference mechanical indentation standards within +/- 2.5%, delivering quantitative tissue stiffness measurements without liquid coupling artifacts.

 

Applications

 

Ultrasound-Guided Central Venous & Arterial Line Catheterization (ICU, Anesthesiology & Vascular Access)

Sourced in high container volumes by hospital intensive care consortiums, surgical anesthesia departments, and medical kit assemblers bundling vascular catheterization trays; gamma-sterilized Dia 60 mm or 50x70 mm solid coupling pads are placed directly over sterile internal jugular, subclavian, or femoral vascular sites, allowing physicians to guide needle cannulation through the sterile pad without liquid gel contaminating the puncture tract or weakening post-procedure transparent dressing adhesion.

 

Emergency Medicine & Military Field Trauma Point-of-Care Ultrasound (POCUS)

Deployed across emergency medical services (EMS), disaster response units, and trauma resuscitation suites performing focused assessment with sonography for trauma (FAST scans); pre-packaged solid pads allow emergency physicians to initiate chest and abdominal ultrasound evaluations in seconds without searching for gel bottles, squeezing sticky fluids over trauma patients, or wiping down muddy transducers in resource-constrained environments.

 

Liver Fibrosis Staging & Musculoskeletal Shear-Wave Elastography (SWE)

Sourced by hospital gastroenterology imaging centers, hepatitis clinics, and sports medicine biomechanics laboratories operating high-end ultrasound platforms equipped with quantitative elastography packages; the elastic solid hydrogel provides continuous shear-wave transmission without fluid boundary slippage, enabling accurate Young's modulus (kPa) quantification of liver stiffness and Achilles tendon elasticity without liquid artifact distortions.

OEM & Private Label

 

  • Pad Geometries, Adhesive Film Borders & Custom Sterile Packaging : We provide modular turnkey contract manufacturing and packaging options for medical imaging hardware OEMs and interventional consumable brands:

    • Footprint Geometry Matrix: Universal Circular Discs in Dia 40 mm (pediatric/vascular), Dia 60 mm (standard linear probes), and Dia 80 mm (abdominal curved arrays); Rectangular formats in 50x70 mm and 80x100 mm (wide-format MSK linear arrays).

    • Thickness Profiling Matrix: Standard 2.0 mm (zero-depth shift for precision vascular puncture); Extended 2.5 mm (universal POCUS scanning); and Heavy 3.0 mm (high-compliance padding for bony joint surfaces).

    • Optional Integrated Adhesive Surgical Film Borders: Available as a standalone elastomeric pad, or manufactured with a perimeter medical polyurethane (PU) adhesive border that anchors the solid pad securely to the patient's skin, creating a sterile barrier drape around the needle entry site.

    • Sterility & Barrier Packaging Options: Terminal gamma-sterilized individual peel-pouches (ISO 11137 verified with medical Tyvek lidding for direct placement onto sterile surgical tables); or economic non-sterile multipacks for diagnostic outpatient screening. Packaging options include multi-color packaging printing, customized catheterization kit layouts, and serialized GS1/UDI barcodes. 

     

  • Two-Center Supply Chain Mechanics : High-purity deionized water generation, proprietary solid hydrogel chemical synthesis, high-vacuum centrifugal degassing, precision slot-die extrusion, and in-process acoustic velocity testing execute natively inside our primary China facility (ISO 13485:2016 and FDA registered under 21 CFR 820). Automated die-cutting, automated blister tray heat-sealing, terminal gamma sterilization coordination, secondary sterile cartoning, and palletized ocean container export route through our Vietnam hub, shielding international B2B buyers from Section 301 tariffs and regional medical consumable import barriers.

 

Certifications

 

  • ISO 10993 Comprehensive Dermal & Breached-Skin Biocompatibility : Master production lots undergo testing in accredited independent GLP testing laboratories confirming strict compliance with ISO 10993-5 (In Vitro Cytotoxicity: Grade 0, non-cytotoxic), ISO 10993-10 (Skin Sensitization: 0% allergic response in guinea pig maximization assays), and ISO 10993-23 (Primary Dermal Irritation Index = 0.0, non-irritating). The solid hydrogel matrix is certified 100% natural rubber latex-free, animal-gelatin-free, phthalate-free, non-toxic, and biocompatible for contact with open needle-puncture wounds. 

     

  • ISO 11137 Radiation Sterilization Validation : For sterile product lines, packaging lots undergo validation under ISO 11137-1 and ISO 11137-2 (Sterilization of health care products - Radiation). Dose-setting audits confirm that the validated gamma radiation sterilization dose achieves an unbroken Sterility Assurance Level (SAL) of 10-6 with zero degradation of acoustic sound velocity, mechanical tensile strength, or surface friction characteristics. 

     

  • IEC 60601-2-37 & ASTM E494 Acoustic Safety and Performance : Master production lots undergo acoustic transmission verification confirming full compliance with ASTM E494 (Measuring Ultrasonic Velocity in Materials) and IEC 60601-2-37 diagnostic acoustic safety guidelines. The formulation guarantees acoustic velocity of 1540 m/s (+/- 8 m/s), acoustic impedance of 1.54 MRayls (+/- 0.02 MRayls), and high-frequency insertion loss below 0.06 dB/cm-MHz across broad clinical bandwidths. 

     

  • MDSAP & ISO 13485 Manufacturing System Controls : Monomer synthesis vessels, vacuum degassing bays, and blister cleanroom packaging lines operate strictly under certified ISO 13485:2016 and MDSAP regulatory frameworks (covering US FDA 21 CFR 820, Health Canada, TGA Australia). Unbroken electronic Device History Records (DHR) capture bulk deaeration vacuum levels, ultrasound velocity logs, acoustic attenuation curves, needle-puncture mechanical load records, and blister seal burst-pressure data across every manufactured production lot.

 

Technical FAQ

Q: Why does using liquid ultrasound gel during central venous access risk catheter-related bloodstream infections (CRBSI), and how does a solid coupling pad eliminate needle-tract contamination?

  

A: The risk of catheter-related bloodstream infections from liquid ultrasound gel stems from the fluid's ability to act as a microbial reservoir and its capillary transport into puncture wounds: The Pathophysiology of Gel-Induced Bloodstream Seeding: In hospital clinical environments, multi-use squeeze bottles of ultrasound gel are handled repeatedly by medical staff. Bacteria enter through the dispensing nozzle or air drawn back into the container: 1. Microbial Colonization: Pathogens such as Burkholderia cepacia, Pseudomonas aeruginosa, and Klebsiella pneumoniae thrive inside aqueous, non-sterile gels, forming protective bacterial biofilms within the bottle. 2. Capillary Adhesion to the Needle Shaft: When a physician performs ultrasound-guided needle puncture through a layer of liquid gel, the fluid clings to the metal needle through surface tension and viscous drag. 3. Subcutaneous Inoculation: As the needle passes through the skin, the fluid gel is deposited along the entire subcutaneous puncture tract and introduced directly into the vascular lumen. 4. Catheter Biofilm Formation: When the indwelling catheter is advanced over the guidewire through this contaminated tract, the bacteria transfer to the catheter's external surface. The microbes produce extracellular polymeric substances, creating an antibiotic-resistant biofilm that seeds recurrent bacteremia (CRBSI) and sepsis. Our Solid Coupling Pad Sterile Barrier Solution: The Solid Ultrasound Coupling Pad eliminates puncture-tract contamination through complete fluid elimination: 1. Zero-Liquid Elastomeric Slab: The pad is synthesized as a dense, crosslinked solid hydrogel with zero loose, unbound liquid phase. There is no fluid to cling to needle shafts, run across the skin, or wick beneath sterile drapes. 2. Clean Puncture Penetration: The pad is supplied sterile (SAL 10^-6 verified via ISO 11137). When the vascular needle punches through the solid hydrogel, the material deforms elastically without coring, crumbling, or leaving microscopic fragments. 3. Pristine Skin Field: The needle enters the skin completely clean and dry. No foreign fluid is transported into subcutaneous tissues or blood vessels, halting bacterial inoculation and leaving the skin dry for immediate, secure adhesion of sterile transparent dressings.

Q: How does a solid coupling pad allow transverse shear waves to propagate accurately during Shear-Wave Elastography (SWE) where liquid gel causes boundary slippage?

A: The accuracy of Shear-Wave Elastography (SWE) across couplant boundaries depends on the presence of a non-zero shear elastic modulus at the interface: The Physics of Liquid Gel Boundary Slippage in SWE: Diagnostic shear-wave elastography calculates tissue stiffness (Young's modulus E in kPa) by generating focused acoustic radiation force impulse (ARFI) push-pulses that launch transverse shear waves through tissue. The ultrasound machine monitors the lateral velocity of these shear waves: 1. Zero Shear Modulus in Liquids: In classical continuum mechanics, liquids support longitudinal compressional waves (K > 0) but have zero static shear modulus (G = 0). Liquid ultrasound gels cannot resist or transmit transverse shear displacements. 2. Fluid-Solid Boundary Slip: When transverse shear waves oscillate perpendicular to the longitudinal ultrasound beam, the liquid gel forms an unconstrained fluid boundary layer against the probe lens. The lateral mechanical oscillation is dissipated as viscous shear heat within the fluid. 3. Distorted Velocity Tracking: The ultrasound machine's tracking algorithms assume continuous elastomeric contact. Because the liquid layer slips, lateral displacement tracking registers boundary phase noise. The calculated shear-wave speed becomes erratic, corrupting liver fibrosis staging and breast lesion stiffness readings. Our Solid Hydrogel Shear Transmission Engineering: Solid Ultrasound Coupling Pads enable clean elastography imaging through solid-phase viscoelastic coupling: 1. Calibrated Elastic Shear Modulus: The crosslinked polyacrylamide-co-polyacrylate polymer network provides a calibrated Young's modulus (E) between 12 and 18 kPa and an acoustic velocity of 1540 m/s, matching human soft tissue. 2. Non-Slip Boundary Continuity: Because the pad is an elastic solid (G > 0), it bonds firmly against both the transducer lens and patient skin. The interface resists lateral slip, supporting the propagation of transverse shear displacements across the boundary. 3. Undistorted Shear Wavefronts: Acoustic radiation force push-pulses pass through the solid pad to generate clean, undistorted transverse shear wavefronts in target tissue. The ultrasound system tracks lateral displacements without boundary noise, delivering quantitative tissue stiffness measurements with accuracy within +/- 2.5% of mechanical indentation standards.

 

 

Ultrasound hardware manufacturers, vascular access kit assemblers, and interventional radiology procurement directors can request official Certificates of Analysis (COA), 1540 m/s acoustic sound velocity testing logs, ISO 11137 radiation sterilization validation dossiers, ISO 10993 biocompatibility lab records, and unbranded evaluation sample packs (including circular Dia 60 mm and rectangular 50x70 mm formats in sterile individual blister trays).

👉 [Request Solid Ultrasound Coupling Pad Evaluation Packs]

 

Hot Tags: solid ultrasound coupling pad, China solid ultrasound coupling pad manufacturers, suppliers, factory

Specifications

 

Analytical Parameter  Engineering Baseline  Testing Standard 
Footprint Assortment  Disk: Dia 40 mm, Dia 60 mm, Dia 80 mm; Rectangular: 50x70 mm, 80x100 mm Die-cut tooling 
Membrane Caliper  2.0 mm, 2.5 mm, and 3.0 mm (+/- 0.2 mm inline tolerance) Precision dial gauge 
Speed of Sound  1540 m/s (+/- 8 m/s at 25C to 37C) ASTM E494 
Acoustic Impedance  1.52 to 1.56 MRayls (Rayls x 10^6 kg/m2-s) Reflection calculation 
Acoustic Attenuation  < 0.06 dB/cm-MHz across 2.0 MHz to 18.0 MHz Frequency Spectrum Transmission insertion loss 
Shear-Wave Transparency  Young's Modulus E: 12 to 18 kPa; Shear Loss Tangent < 0.04 Shear wave elastography phantom 
Kinematic Surface Friction  Dynamic Coefficient of Friction (u): 0.45 to 0.65 on probe lens ASTM D1894 
Polymer Chemistry  Crosslinked Polyacrylamide-Co-Polyacrylate Hydrogel (IPN) Synthetic network 
Mechanical Integrity  Tensile Strength > 1.2 MPa; Needle Puncture Resistance > 15N ASTM D412 
Fluid Phase Migration  0.00% Liquid Exudate (Zero syneresis under 50 kPa normal load) Gravimetric blot assay 
Sterility Assurance  Gamma Radiation Sterilization / Validated SAL 10^-6 ISO 11137 
Biocompatibility Grade  Grade 0 Cytotoxicity; 0% Sensitization; Primary Irritation = 0.0 ISO 10993 compliant 
Primary Packaging  Thermoformed PETG Blister with Tyvek Lid or Foil Peel-Pouch Multi-layer barrier 
Contract Manufacturing MOQ  5,000 Units (Custom die-cutting / sterile pouching: 10,000 units) Factory direct 