B2B contract manufacturing of dual-modality Ultrasonic Conductive Gel for combination therapy (therapeutic ultrasound + TENS/IFC). Features 1540 m/s sound velocity, volume resistivity <18 Ohm-cm, 3.0 W/cm² cavitation resistance, and turnkey OEM packaging.
Product Overview
Ultrasonic Conductive Gel operates as a dual-modality acoustic and electro-conductive transmission fluid engineered for combination electrotherapy systems, phonophoresis delivery, and multi-modal aesthetic hardware. In physical therapy clinics, sports medicine facilities, and rehabilitation suites, combination consoles deliver 1 MHz or 3 MHz therapeutic ultrasound through a metallic transducer soundhead while concurrently routing electrical stimulation currents (such as interferential, premodulated, high-voltage pulsed, or TENS waveforms) through the same metal applicator face. Operating under continuous acoustic power densities up to 3.0 W/cm² and electrical loads up to 50 mA RMS, this gel bridges the boundary between the oscillating metallic soundhead and biological soft tissue, transferring mechanical vibrational waves and electrical current vectors without energy dissipation.
Deploying standard diagnostic ultrasound couplants or generic TENS electrode lubricants in combination electro-ultrasound therapies leads to three severe acoustic, electrical, and metallurgical breakdowns:
- Acoustic Wave Reflection and Piezoelectric Crystal Cracking from Cavitation Voids: Standard diagnostic ultrasound gels are formulated purely for low-power imaging (<0.1 W/cm²). When subjected to continuous therapeutic acoustic power levels (1.0 to 3.0 W/cm²), microscopic dissolved air pockets nucleate and undergo violent acoustic cavitation. The resulting dense micro-bubble cloud acts as a total acoustic reflection wall. Over 70% of the acoustic energy reflects back into the transducer soundhead, superheating the internal piezoelectric ceramic disc (PZT) past its Curie point and permanently cracking the transducer bond.
- Focal Electrical Hot Spots and Cutaneous Arc Burns from Erratic Conductivity: Standard diagnostic ultrasound gels possess low, uncalibrated electrical conductivity (often relying on tap water with resistivities exceeding 2,000 Ohm-cm). When a physical therapy console discharges electrical stimulation through the soundhead, the high-resistance fluid blocks uniform current transfer. Current concentrates through tiny residual low-resistance pathways, spiking localized current density past 3.0 mA/cm² and causing painful electrical pinpricks and epidermal burns.
- Galvanic Pitting and Metal Salt Leaching on Transducer Soundheads: Therapeutic soundheads feature machined aluminum alloy, medical titanium, or chrome-plated stainless steel applicator faces. When high-frequency current passes through standard unbuffered gels, the metallic face acts as an active anode. Unbuffered chloride ions trigger rapid galvanic pitting corrosion, eating microscopic craters into the mirror-polished soundhead and leaching toxic metal salts directly onto the patient's skin.
The Ultrasonic Conductive Gel manufacturing platform eliminates these operational hurdles through targeted chemical and rheological formulation: a dual-modality matrix matching biological soft tissue with an exact acoustic velocity of 1540 m/s and an acoustic impedance of 1.54 MRayls, while delivering stable volume resistivity below 18 Ohm-cm; a high-vacuum centrifugal deaeration process that eliminates acoustic cavitation nucleation sites up to 3.0 W/cm²; and an organic buffering complex that passivates metallic transducer faces against galvanic pitting. We contract-manufacture private-label squeeze bottles, dispensing pumps, and clinic cubitainers for physical therapy device OEMs, rehabilitation hospital networks, and medical supply distributors globally.
Technical & Engineering Description
The industrial synthesis and automated packaging of Ultrasonic Conductive Gel execute inside ISO 13485-certified Class 8 cleanrooms across closed-loop 316L stainless steel reaction platforms equipped with sub-micron vacuum homogenizers, high-torque planetary sweepers, and automated rotary bottling lines. Compounding operates across five coordinated engineering stages:
- Stage 1: Multi-Pass EDI Water Purification & Acoustic-Electrolytic Dual Titration: Raw process water passes through dual-pass reverse osmosis (RO) coupled with continuous electrodeionization (EDI), driving baseline electrical conductivity below 0.08 uS/cm. The deionized water charges into jacketed 316L stainless steel reaction vessels and is heated to 72°C. A calculated fraction of pharmaceutical-grade electrolyte buffer (combining sodium chloride, potassium phosphate, and organic carboxylates) is metered into the bulk alongside bio-fermented sodium hyaluronate. This titration balances longitudinal sound velocity to 1540 m/s and sets bulk volume resistivity below 18 Ohm-cm, ensuring the fluid satisfies acoustic and electrical transfer thresholds concurrently.
- Stage 2: Vacuum Sub-Surface Induction & High-Electrolyte Polymer Solvation: High-molecular-weight crosslinked polyacrylic polymers-specifically modified with polar side-chains to resist coil collapse in high-electrolyte environments-are inducted into the fluid vortex via sub-surface vacuum powder induction ports at 2,800 RPM. Introducing the polymer directly beneath the liquid surface eliminates dry agglomeration and fish-eye lumps. Planetary counter-rotating anchor sweepers operate at 35 RPM for 45 minutes, allowing polymer chains to fully hydrate in the presence of dissolved ionic salts without mechanical chain fracture.
- Stage 3: Polyol Thermal Passivation & Stoichiometric Neutralization: The reaction vessel circulates chilled glycol water through its jackets to cool the bulk matrix to 30°C. A non-crystallizing ternary humectant phase-combining pharmaceutical vegetable glycerol, bio-fermented 1,3-propanediol, and low-molecular polyethylene glycol (PEG-400)-is metered into the bulk. Stoichiometric neutralization brings the pH to 6.50 (±0.20) using analytical-grade alkanolamine buffers. Neutralization ionizes carboxylate pendant groups, establishing a dense 3D viscoelastic grid characterized by a high static yield stress and dynamic shear-thinning response.
- Stage 4: Extreme High-Vacuum Cavitation Scrubbing & Centrifugal Deaeration: The compounding vessel is sealed and drawn down to an internal vacuum level of -0.098 MPa. A bottom-mounted high-shear stator-rotor homogenizer runs at 3,500 RPM for 40 minutes under active vacuum. This mechanical action pulls entrained micro-air bubbles and dissolved atmospheric gases out of the high-viscosity matrix. Deaeration continues until internal micro-bubble counts drop to zero under automated laser obscuration particle counters, ensuring that continuous therapeutic ultrasound up to 3.0 W/cm² will not nucleate cavitation voids or reflect acoustic energy during combination therapy.
- Stage 5: Sanitary Cartridge Micro-Filtration & High-Speed Packaging: Finished gel passes through a 20 µm sanitary stainless steel cartridge filter directly to automated rotary filling carousels. Medical-grade high-density polyethylene (HDPE) squeeze bottles (250 ml or 500 ml) are loaded, ionized-air cleaned, and bottom-filled using servo-driven ceramic positive-displacement pistons to eliminate product stringing. Bottles receive induction-bonded aluminum barrier pull-tab liners, are capped with precision flip-top dispensing closures, and are stamped with inkjet lot numbers and expiration dates. Master cartons pass dynamic check-weighing and automated packaging. The baseline contract manufacturing MOQ is 5,000 units.
Key Features
-
Synchronous Acoustic-Electric Impedance Matching (Simultaneous 1540 m/s Sound Transmission and Sub-18 Ohm-cm Electrical Conduction)
In combination physical therapy, an ultrasound soundhead acts simultaneously as a high-frequency acoustic emitter and an active electrical stimulation electrode:
1. The Dual-Failure Physics of Single-Modal Gels: Diagnostic ultrasound couplants prioritize low acoustic attenuation but possess high electrical resistance (>2,000 Ohm-cm), blocking current and burning skin. Conversely, standard TENS gels prioritize low electrical resistance (<15 Ohm-cm) but contain dense suspended micro-bubbles and unadjusted sound speeds, attenuating over 50% of therapeutic acoustic energy and overheating the applicator.
2. Our Dual-Matching Matrix: Ultrasonic Conductive Gel matches human soft tissue across mechanical and electrical domains simultaneously:
• Acoustic Domain: Long-chain polymers and structured water phases are balanced to deliver a longitudinal acoustic velocity of 1540 m/s (±10 m/s) and an acoustic impedance of 1.54 MRayls. Acoustic reflection at the soundhead-skin interface is suppressed below 0.1%, channeling 1 MHz and 3 MHz soundwaves into target tissues with attenuation under 0.10 dB/cm-MHz.
• Electrical Domain: The fluid incorporates a calibrated organic electrolyte buffer that maintains bulk volume resistivity below 18 Ohm-cm (electrical conductivity 1.0 to 1.6 mS/cm).
3. Isotropic Current Vectoring: When 50 mA electrical stimulation pulses fire through the soundhead, the conductive matrix distributes charge evenly across the entire metal face. Focal current crowding is completely eliminated, allowing high-intensity therapeutic ultrasound and deep-penetrating electrotherapy to operate concurrently through a single contact layer without skin stinging or acoustic signal loss.
-
High-Intensity Acoustic Cavitation Suppression (Stabilizing Fluid Integrity Under 3.0 W/cm² Continuous Therapeutic Ultrasound)
Therapeutic ultrasound delivers sustained acoustic energy (1.0 to 3.0 W/cm²) to heat deep joint capsules, break down scar adhesions, and increase collagen extensibility:
1. The Cavitation Breakdown in Aerated Gels: Standard gels contain thousands of microscopic air voids. When subjected to continuous 3.0 W/cm² acoustic radiation at 1 MHz or 3 MHz, the alternating acoustic pressure field exceeds the cavitation threshold of these micro-voids.
2. Bubble Cloud Reflection: The micro-bubbles expand violently and undergo inertial cavitation, growing into an opaque white bubble cloud. Air has an acoustic impedance of only 0.0004 MRayls (compared to 1.54 MRayls for gel). The bubble cloud acts as a mirror, reflecting up to 70% of the forward acoustic energy back toward the soundhead.
3. Piezoelectric Transducer Failure: The reflected acoustic wave packets strike the piezoelectric ceramic elements (PZT) inside the applicator face. The PZT crystal converts the reflected energy into heat, raising internal transducer temperatures past 60°C. The internal bonding epoxy degrades, the crystal suffers thermal depolarization, and the expensive therapeutic soundhead cracks permanently. We eliminate acoustic cavitation through closed-loop molecular and degassing engineering:
4. Extreme Vacuum Centrifugal Degassing (-0.098 MPa): Compounded batches undergo centrifugal scouring under deep vacuum, stripping out dissolved atmospheric gases and reducing the micro-bubble count to zero.
5. Intermolecular Cavitation Shielding: The polyacrylate-polyol network possesses high dynamic extensional elasticity that dampens acoustic micro-streaming around potential nucleation sites, raising the acoustic cavitation threshold above 3.5 W/cm². Under hydrophone testing measuring through-transmission acoustic power at continuous 3.0 W/cm² for 30 minutes, our gel demonstrated zero bubble nucleation, zero acoustic clouding, and consistent forward power transfer exceeding 95%, keeping transducer soundheads cool and protecting expensive PZT crystals from thermal cracking.
-
Transducer Face Metallurgical Passivation (Inhibiting Anodic Galvanic Pitting and Metal Salt Leaching on Aluminum/Titanium Soundheads)
In combination therapy, the metallic soundhead is electrically energized to deliver stimulation pulses:
1. The Anodic Corrosion Problem: Therapeutic soundheads are machined from aircraft-grade aluminum alloys (such as 6061-T6), titanium, or chrome-plated brass. During the electrical stimulation phase, current flow polarizes the soundhead, turning the metallic face into an active electrochemical anode.
2. Pitting by Halide Attack: Standard conductive primers rely on inorganic chloride salts (NaCl) for conductivity. Driven by the anodic electric potential, mobile chloride ions migrate toward the metal applicator. The aggressive halide ions penetrate microscopic defects in the metal's natural oxide passivation layer, initiating rapid pitting corrosion. Within weeks of clinical use, the mirror-polished soundhead develops dark, rough craters. These microscopic pits harbor bacterial biofilms, scratch patient skin during rotational massage, and leach metallic nickel, aluminum, and chromium ions into tissue. We resolve transducer degradation through active metallurgical passivation:
3. Halide-Free Organic Osmolyte Buffering: Electrical conductivity is established through bulky organic carboxylates and phosphate buffers rather than free chloride salts, eliminating aggressive halide attack vectors.
4. Interfacial Corrosion Inhibitors: The aqueous vehicle compounds organic corrosion inhibitors that coordinate with surface metal atoms, forming a monomolecular protective passivation layer over aluminum and titanium applicator faces. In accelerated electrochemical polarization testing conforming to ASTM G48 protocols (subjecting aluminum and titanium soundheads to continuous electrical currents in gel baths for 72 hours), our formulation demonstrated Grade 0 pitting, zero weight loss, and zero surface discoloration, keeping expensive combination therapy applicators smooth and preventing metallic contamination.
Applications
Clinical Rehabilitation & Sports Medicine Combo Consoles (Ultrasound + IFC/TENS Synchronous Therapy)
Sourced in high volume by physical therapy departments, orthopedic rehabilitation centers, and professional sports team training rooms operating multi-channel combination workstations (e.g., Chattanooga Intelect, BTL, Gymna); therapists apply the high-viscosity gel over reusable metallic soundheads, simultaneously administering 1 MHz/3 MHz deep thermal ultrasound alongside interferential (IFC) or premodulated electrical stimulation for chronic lower back pain, calcific tendinitis, and joint contractures without electrical hot spots or transducer overheating.
Phonophoresis & Transdermal Anti-Inflammatory Drug Infusion
Deployed across pain management clinics and rheumatology practices performing phonophoresis protocols (delivering topical NSAIDs, dexamethasone, or herbal analgesics through intact skin); the zero-cavitation acoustic matrix transfers ultrasonic radiation pressure to open transient intercellular lipid pathways in the stratum corneum, while electrical micro-vectors drive ionized therapeutic molecules deep into inflamed bursae, epicondyles, and arthritic joints without thermal degradation of active ingredients.
Multi-Modal Aesthetic Body Sculpting & Facial Toning Hardware (Acoustic + RF / Micro-EMS Platforms)
Sourced by aesthetic clinic networks and medical spa chains utilizing multi-functional contouring hardware that integrates ultrasonic fat cavitation/thermal tightening with multi-polar radiofrequency (RF) or micro-EMS muscle stimulation; the dual-modality couplant enables moving treatment heads to transmit high-frequency acoustic waves and electrical RF current simultaneously across a single application layer, wiping completely clean with damp towels after 30-minute sessions.
OEM & Private Label
-
Container Packaging Options, Dispensing Closures & Custom Brand Packaging : We provide comprehensive contract manufacturing and formulation adjustments for private-label physical therapy brands and medical supply chains:
• Container Formats: Standard 250 ml ergonomic HDPE squeeze bottles with ribbed non-slip finger grips; professional 500 ml cylindrical HDPE bottles with lockable dispensing pumps; and heavy-duty 5-liter clinical cubitainers with integrated dispensing spigots and auxiliary refill funnels for high-turnover clinic backbars.
• Dispensing Closure Types: Precision flip-top dispensing caps with orifice diameters from 2.5 mm to 4.0 mm (calibrated to dispense exact gel beads onto circular ultrasound soundheads); push-pull directional spouts; and high-viscosity spring-loaded lotion pumps engineered to dispense viscous gels without product air-locking.
• Acoustic & Viscosity Customization: Standard clear transparent gel; optional clinic blue tint (FD&C Blue #1); and adjustable viscosity tiers (Light Flow at 45,000 cP for large-area body strokes vs High Body at 65,000 cP for vertical joint contour retention).
• Turnkey Packaging Customization: Multi-color offset and silk-screen bottle printing, wrap-around high-gloss poly labels, custom folding retail cartons, Amazon-compliant FNSKU barcodes, and serialized GS1/UDI tracking codes.
-
Two-Center Supply Chain Mechanics : High-purity deionized water generation, polymer synthesis, high-shear vacuum homogenization, centrifugal bubble degassing, and bulk analytical quality assurance execute natively inside our primary China facility (ISO 13485:2016 and FDA registered under 21 CFR 820). Automated bottle blow-molding, cleanroom rotary filling, induction foil heat-sealing, retail kit boxing, and palletized ocean container export route through our Vietnam manufacturing hub, shielding international B2B buyers from Section 301 tariffs and regional consumable import barriers.
Certifications
-
ISO 10993 Comprehensive Dermal Biocompatibility : Master production lots undergo testing in accredited independent GLP testing laboratories confirming strict compliance with ISO 10993-5 (In Vitro Cytotoxicity: Grade 0, non-cytotoxic), ISO 10993-10 (Skin Sensitization: 0% allergic response in guinea pig maximization assays), and ISO 10993-23 (Primary Dermal Irritation Index = 0.0, non-irritating). The formula is certified 100% natural rubber latex-free, phthalate-free, non-greasy, water-soluble, and non-sensitizing over prolonged daily clinical contact.
-
IEC 60601-2-5 & IEC 60601-2-10 Specialized Medical Standards : Formulated to satisfy international electrotherapy and ultrasound safety criteria:
• Compliant with IEC 60601-2-5 (Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment), ensuring uninterrupted forward acoustic power transmission up to 3.0 W/cm² with beam non-uniformity ratios (BNR) preserved below 5.0:1.
• Compliant with IEC 60601-2-10 (Particular requirements for the basic safety and essential performance of nerve and muscle stimulators), maintaining uniform electrical current density below 2.0 mA RMS/cm² across the entire soundhead face under 50 mA combined loads.
-
Microbiological Purity & Antimicrobial Preservation : Formulated in compliance with USP <51> Antimicrobial Effectiveness Testing, demonstrating rapid 28-day challenge reduction of bacteria, yeasts, and molds without relying on skin-sensitizing parabens or formaldehyde releasers. Certified compliant with USP <61>/<62> microbiological limits: Total Aerobic Microbial Count (TAMC) < 10 CFU/g, Total Yeast and Mold Count (TYMC) < 10 CFU/g, and verified total absence of Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, and Candida albicans.
-
MDSAP & ISO 13485 Manufacturing System Controls : Compounding suites, cleanroom bulk storage, and automated rotary bottling bays operate under certified ISO 13485:2016 and MDSAP regulatory frameworks (covering US FDA 21 CFR 820, Health Canada, TGA Australia). Unbroken electronic Device History Records (DHR) capture bulk deaeration vacuum levels, ultrasound sound velocity verification logs, electrical conductivity, and automated fill weights across every manufactured production lot.
Technical FAQ
Q: Why does using ordinary diagnostic ultrasound gel during electro-ultrasound combination therapy cause sharp electric shocks and skin burns?
A: The sharp stinging and burn risks of using diagnostic gel during combination therapy stem from non-uniform electrical resistance distribution and localized current crowding: The Physics of Failure in Diagnostic Gels: Diagnostic ultrasound couplants are designed exclusively for acoustic transmission during low-power imaging. They are synthesized using deionized water thickened with uncharged polymers, deliberately formulated with near-zero salt concentrations to avoid probe lens degradation. Consequently: 1. High Electrical Volume Resistivity: Diagnostic gel has a volume resistivity exceeding 2,000 Ohm-cm, behaving as a poor electrical conductor (near-insulator). 2. Current Channeling and Hot Spots: In combination therapy, the metal ultrasound soundhead discharges therapeutic electrical currents (such as 30 to 50 mA of interferential or TENS pulses). Because the high-resistance gel layer resists current flow, current cannot distribute evenly across the broad 5 cm² or 10 cm² applicator face. 3. Dielectric Pinhole Breakdown: Current is forced through random micro-channels of lowest resistance-such as localized sweat pores, hair follicles, or areas where probe downward pressure thins the gel layer. 4. Cutaneous Arc Discharges: Localized current density spikes past safe biological limits (>2.0 mA/cm²). The patient experiences sharp, painful "electrical bites" and burning sensations. If the soundhead is held stationary, this focal current crowding induces partial-thickness dermal burns beneath the acoustic applicator. Our Dual-Modality Conductive Solution: Ultrasonic Conductive Gel eliminates hot spots through calibrated ionic conduction: 1. Engineered Electrolyte Reserve: The formulation incorporates an isotonic organic electrolyte buffer that sets bulk volume resistivity strictly below 18 Ohm-cm (conductivity 1.0 to 1.6 mS/cm). 2. Equipotential Surface Distribution: The conductive gel turns the entire contact layer into an equipotential electrical plane. Electrical stimulation pulses spread evenly across the entire surface area of the metal soundhead. 3. Sub-Sensory Electrical Transition: Current transfers into biological tissue in a broad, low-density wave (current density held strictly below 0.5 mA/cm² under standard 50 mA therapy). The electrical stimulation feels smooth, deep, and comfortable, eliminating pinprick shocks and allowing full-power electro-ultrasound combination therapy without dermal burns.
Q: How does acoustic cavitation suppression prevent therapeutic ultrasound soundheads from overheating and cracking piezoelectric crystals under 2.5 W/cm² continuous output?
A: Transducer soundhead overheating and piezoelectric crystal failure are caused by acoustic reflection off cavitation-induced micro-bubble clouds: The Cavitation Reflection Hazard: Therapeutic ultrasound operates at sustained acoustic power levels (1.0 to 3.0 W/cm²) that are 30 to 100 times higher than diagnostic imaging levels. In basic, un-degassed gels: 1. Cavitation Nucleation: The intense acoustic pressure waves (P > 0.5 MPa) cause dissolved microscopic air bubbles in the gel to expand, resonate, and collapse (inertial cavitation). 2. Formation of an Acoustic Barrier: As cavitation progresses, these micro-cavities merge into a dense, macroscopic bubble cloud directly beneath the applicator face. Because air has a near-zero acoustic impedance (0.0004 MRayls) compared to gel (1.54 MRayls), the bubble cloud acts as a total acoustic reflection barrier. 3. Acoustic Wave Bounce-Back: Up to 70% of the forward ultrasonic energy reflects back into the soundhead face. 4. Thermal Destruction of the PZT Crystal: The reflected acoustic energy cannot escape into biological tissue; instead, it is absorbed by the metal applicator face and the underlying piezoelectric lead zirconate titanate (PZT) crystal. The temperature of the internal crystal rapidly climbs past 60°C to 80°C. This extreme heat degrades the bonding epoxy holding the crystal to the faceplate, induces thermal depolarization of the piezoelectric ceramic (Curie transition), and causes catastrophic mechanical stress fractures across the crystal disc. Our Cavitation-Suppression Engineering Solution: Ultrasonic Conductive Gel protects therapeutic transducers through dual degassing and rheological stabilization: 1. Sub-Micron Vacuum Degassing (-0.098 MPa): Compounded batches undergo centrifugal scouring under deep vacuum, stripping out dissolved atmospheric gases and reducing internal micro-bubble counts to zero. Without seed bubbles, acoustic cavitation cannot nucleate. 2. Viscoelastic Void Dampening: The crosslinked polyacrylate-polyol framework possesses high dynamic extensional elasticity that resists void expansion under intense acoustic pressure swings. In continuous acoustic hydrophone power testing delivering 3.0 W/cm² continuous 1 MHz ultrasound for 30 minutes, our gel maintained forward acoustic transmission above 95% with zero bubble formation. Applicator face temperatures remained stable below 41°C, eliminating reflected thermal shock and protecting expensive PZT crystals from thermal cracking.
Physical therapy equipment manufacturers, clinical rehabilitation directors, and medical consumable distributors can request official Certificates of Analysis (COA), 3.0 W/cm² acoustic cavitation transmission laboratory traces, ASTM G48 metallurgical anti-corrosion logs, ISO 10993 biocompatibility testing dossiers, and unbranded evaluation sample packs (including 250 ml squeeze bottles and 500 ml pump containers).
👉 [Request Ultrasonic Conductive Gel Evaluation Sample Packs]
Hot Tags: ultrasonic conductive gel, China ultrasonic conductive gel manufacturers, suppliers, factory
Specifications
| No. | Item No | Volume | Package |
| 1 | TG-65ML | 65ml/2.3oz | 200pcs/carton, Carton dimession: 43cm*36cm*28cm, Gross weight: 14.5kgs |
| 2 | TG-90ML | 90ml/3.2oz | 160pcs/carton, Carton dimession: 43cm*36cm*28cm, Gross weight: 16kgs |
| 3 | TG-100ML | 100ml/3.5oz | 160pcs/carton, Carton dimession: 48cm*40cm*33cm, Gross weight: 17.5kgs |
| 4 | TG-150ML | 150ml/5.3oz | 160pcs/carton, Carton dimession: 48cm*40cm*33cm, Gross weight: 17kgs |
| 5 | TG-250ML | 250ml/8.9oz | 50pcs/carton, Carton dimession: 40cm*30cm*30cm Gross Weight:17kgs |