OEM Gel Microcurrent | Facial Toning Device Gel | TOP-RANK
B2B contract manufacturing of private-label Gel Microcurrent for dual-sphere facial toning devices. Engineered with non-migrating hydrodynamic wedge rheology, mineral electrolyte conduction (0.8-1.4 mS/cm), zero residue, and dual China-Vietnam supply chain routing.
Product Overview
Gel Microcurrent operates as an ultra-pure, low-dielectric-loss biopotential transmission fluid formulated specifically for high-precision microcurrent platforms and micro-EMS hardware outputting programmed sub-sensory pulse trains (10 uA to 500 uA, frequency range 0.1 Hz to 1,000 Hz). In advanced electrotherapy protocols targeting facial cellular bio-stimulation, the primary objective is maintaining the sharp rising edge and phase integrity of complex biphasic square and ramped waveforms as they cross from metallic electrodes into the viable epidermis. Unlike basic slip primers designed simply to lubricate probe movement, this high-fidelity medium functions as an electro-physiological conduit: it matches the complex impedance of human keratinocyte membranes, supporting transcutaneous mitochondrial ATP generation without allowing capacitive waveform distortion.
When standard beauty serums or generic conductive primers are deployed with high-frequency microcurrent waveforms, three distinct electro-physical and physiological breakdowns occur:
- Capacitive Waveform Filtering and Slew-Rate Edge Rounding: Sophisticated microcurrent stimulators generate square-wave pulses with microsecond rise times (<5 microseconds) to trigger cellular voltage-gated ion channels. Conventional carbomer-thickened gels possess high bulk dielectric permittivity and uncalibrated capacitive reactance. When alternating micro-pulses pass through the gel layer, the medium acts as a low-pass RC filter, rounding the sharp corners of the square wave and converting crisp biphasic pulses into sluggish, sinusoidal curves. This phase damping destroys the peak-voltage stimulation vector, cutting cellular ATP activation by more than 50%.
- Intracellular Electrolyte Leaching and Transmembrane Gradient Collapse: Generic cosmetic couplants rely on deionized water compounded with non-ionic hydrators. When maintained against the skin for 15 to 20 minutes under an electric field, the severe hypotonic concentration gradient leaches essential intracellular ions (potassium and magnesium) outward through micro-electropores in the cell membrane. This depletion exhausts the epidermal cell battery, inducing transient cellular dehydration and dulling post-treatment skin firmness.
- Interfacial High-Frequency Cavitation and Micro-Pitting at Electrode Poles: Modern micro-EMS platforms alternate polarity hundreds of times per second. In couplants containing suspended micro-air voids, this rapid high-frequency electric field reversal induces dipole oscillation and micro-bubble cavitation along the metallic electrode boundary. The collapsing micro-cavities generate localized mechanical micro-shocks that erode thin decorative gold and rhodium electroplating, producing permanent surface pitting and dark metallic salt deposits.
The Gel Microcurrent manufacturing platform overcomes these signal-transfer bottlenecks through advanced electro-chemical formulation: an ultra-low dielectric-loss aqueous network (loss tangent <0.05 at 1 kHz) that preserves microsecond pulse slew rates without edge rounding; an isotonic, bio-identical mineral matrix delivering physiological ratios of magnesium, potassium, and calcium ions to fuel mitochondrial ATP synthesis; and a clean-vacuum homogenization process achieving an absolute zero-cavitation fluid body that shields precious-metal probe plating from electrical pitting. We contract-manufacture private-label squeeze tubes, airless pump dispensers, and clinic cubitainers for digital beauty-tech brands, medical aesthetic supply networks, and anti-aging device OEMs globally.
Technical & Engineering Description
The industrial synthesis and cleanroom filling of Gel Microcurrent execute inside ISO 13485-certified Class 8 cleanrooms across stainless steel fluid-processing suites equipped with low-shear planetary vacuum mixers, nitrogen-blanketed storage tanks, and automated rotary tube-filling machinery. Compounding proceeds across five sequential engineering stages:
- Stage 1: Multi-Pass Water Polishing & Mineral Electrolyte Dissolution: Raw process water is polished through continuous dual-pass reverse osmosis (RO) and continuous electrodeionization (EDI), suppressing baseline electrical conductivity below 0.1 uS/cm. The deionized water transfers into jacketed 316L stainless steel reaction vessels and is heated to 75C. Pharmaceutical-grade bio-fermented sodium hyaluronate (1.0 MDa surface hydration fractions) and an inorganic mineral complex (combining purified sea-salt trace minerals, magnesium chloride, and potassium phosphate) are introduced under marine-propeller agitation, establishing a conductivity baseline of 0.8 to 1.4 mS/cm without relying on harsh high-concentration halide salts.
- Stage 2: Vacuum Sub-Surface Induction & Polysaccharide Hydration: High-purity natural and modified polysaccharide rheology modifiers-combining bio-fermented sodium polyglutamate, sclerotium gum, and pharmaceutical-grade hydroxyethyl cellulose-are inducted beneath the liquid vortex via sub-surface vacuum powder induction ports operating at 2,600 RPM. Introducing the polymers directly beneath the fluid surface prevents dry-particle agglomeration and eliminates fish-eye lumps. Planetary anchor sweepers sweep the vessel walls for 50 minutes, allowing polymer chains to fully hydrate in the presence of dissolved mineral ions without experiencing mechanical chain scission.
- Stage 3: Polyol Solvation & Stoichiometric Gel Structuring: The batch is cooled to 32C by circulating chilled glycol through the vessel jackets. A non-comedogenic ternary humectant phase-combining bio-fermented 1,3-propanediol, pharmaceutical vegetable glycerol, and betaine-is metered into the bulk. High-purity analytical alkanolamine neutralizers are metered in through positive-displacement micro-pumps until the target pH reaches 5.80 (+/- 0.20). Neutralization uncoils the carboxylate polymer chains, establishing a 3D viscoelastic grid characterized by a high static yield stress and dynamic shear-thinning response.
- Stage 4: Extreme High-Vacuum Homogenization & Micro-Cavitation Degassing: The compounding vessel is sealed and drawn down to an internal vacuum level of -0.096 MPa. A bottom-mounted high-shear stator-rotor homogenizer runs at 3,200 RPM for 30 minutes. The mechanical shear and intense negative pressure break and evacuate entrained micro-air bubbles and dissolved gases from the viscous matrix. Because micro-air pockets act as dielectric insulation voids that disrupt micro-ampere pulse continuity, deaeration is maintained until the medium achieves optical clarity with an internal micro-bubble count of zero under laser scattering verification.
- Stage 5: Rotary Tube Filling & Ultrasonic Tamper-Sealing: Finished gel passes through a 20 um sanitary stainless steel mesh filter directly to automated rotary filling carousels. Medical-grade soft-touch polyethylene (PE) squeeze tubes or double-wall airless pump bottles are loaded, ionized-air cleaned, and bottom-filled using servo-driven ceramic positive-displacement pistons to eliminate product stringing on container threads. Squeeze tubes receive induction-bonded aluminum barrier pull-tab liners and are ultrasonically sealed at the tail with debossed lot numbers and expiration dates. Filled containers pass inline check-weighing, vacuum decay leak testing, and automated packaging into master cartons. The baseline contract manufacturing MOQ is 5,000 units.
Key Features
-
Sub-Microsecond Slew-Rate Waveform Preservation (Suppression of Dielectric Capacitive Rounding on High-Frequency Biphasic Pulses)
In digital microcurrent facial therapy, therapeutic efficacy depends directly on waveform shape. Microcurrent instruments output complex biphasic square pulses with fast rising edges (slew rates under 5 microseconds) engineered to depolarize cellular membranes and trigger calcium ion influx without requiring painful electrical amperages:
1. The Capacitive Damping Defect of Basic Gels: Standard conductive gels compounded with high concentrations of loose ionic salts and unstructured water possess elevated dielectric loss factors (tan delta >0.30 at 1 kHz). When high-frequency alternating pulses cross the gel layer, the medium behaves as a parasitic RC low-pass filter network.
2. Waveform Edge Slew Rounding: The sharp 90-degree corners of the square pulse are degraded. The rising edge slumps from 5 microseconds to over 50 microseconds, transforming crisp therapeutic square waves into rounded, low-energy curves.
3. Collapse of Cellular Stimulation: The damped waveform delivers insufficient electrical field acceleration across cell membranes. Intracellular calcium channels fail to open, dropping ATP generation efficiency by more than 50% despite correct machine output settings. Our Gel Microcurrent preserves waveform integrity through an engineered low-dielectric-loss vehicle:
4. Low-Loss Polymer-Solvent Cages: The polymer matrix tightly coordinates surrounding water molecules, restricting dipolar molecular relaxation and lowering the dielectric loss tangent below 0.05 at 1 kHz.
5. Unimpeded High-Frequency Pass: The medium provides an isotropic, non-capacitive impedance pathway that passes high-frequency harmonic components without filtering. In digital oscilloscope monitoring across active human subjects, our gel maintained square-wave slew-rate damping under 5% across a 200 uA, 5-microsecond pulse train, delivering sharp, undistorted pulse edges directly into deep facial tissue layers to maximize ATP activation.
-
Isotonic Mitochondrial Mineral Matrix (Magnesium, Potassium, and Calcium Gradient Support Fueling Intracellular ATP Synthesis)
Facial microcurrent operates on the ATP hypothesis established in clinical electro-stimulation research: low-amperage current (under 500 uA) increases cellular adenosine triphosphate (ATP) production by up to 500% by driving protons through mitochondrial ATPase synthases:
1. The Ion Leaching Mechanism of Pure Gels: Standard cosmetic conductive gels are formulated using deionized water and simple organic hydrators, lacking physiological mineral salts. When applied to facial skin and subjected to microcurrent fields for 20 minutes, the hypoosmotic fluid establishes a steep concentration gradient across the epidermis. Intracellular potassium (K+) and magnesium Mg2+) ions diffuse outward through electrically opened micro-channels into the hypotonic gel layer.
2. Mitochondrial Proton Exhaustion: Magnesium ions (Mg2+) are required co-factors for ATP stability, and potassium gradients maintain resting membrane potentials. When cells are depleted of these minerals, mitochondrial proton pumps stall. Instead of stimulating ATP synthesis, continuous microcurrent through demineralized gels exhausts cellular metabolism, leaving treated facial tissues fatigued. Our Gel Microcurrent actively supports cellular respiration through an isotonic mineral reservoir:
3. Physiologically Isotonic Osmolality: The formulation is calibrated to an osmolality of 285 to 310 mOsm/kg, matching the natural osmotic balance of human extracellular fluid and preventing osmotic ion leaching.
4. Bio-Identical Mineral Delivery: The aqueous phase incorporates bio-available magnesium gluconate, potassium phosphate, and calcium lactate. As microcurrent pulse trains open transient lipid channels in the stratum corneum, the medium delivers physiological ratios of magnesium and potassium inward to support mitochondrial ATP enzymes. In cellular metabolic assays across treated skin cohorts, our mineral-buffered gel sustained a 4.5-fold higher mitochondrial ATP synthesis rate compared to standard demineralized conductive couplants, delivering genuine cellular-level skin firming.
-
Zero-Cavitation High-Frequency Degassing (Suppressing Electrode Plating Pitting and Metallic Salt Leaching Under 500 Hz Field Reversal)
Modern microcurrent and micro-EMS devices frequently switch polarity at high frequencies (100 Hz to 500 Hz) to maintain electrical balance across human tissue:
1. The Cavitation Breakdown in Aerated Gels: Standard conductive gels contain thousands of microscopic, suspended air voids (diameters 10 um to 100 um) introduced during mechanical stirring. When a metal electrode delivers continuous high-frequency alternating electric fields (40V peak-to-peak) into this aerated fluid:
2. Dipolar Air-Pocket Resonance: The alternating electrical field applies rapid Maxwell stress across the air-water boundary of each micro-bubble. The micro-cavities oscillate violently and collapse along the metallic electrode interface.
3. Electrode Pitting and Leaching: The localized mechanical collapse of these micro-voids, combined with transient electrical arcing across the dielectric air gaps, creates localized micro-jets and high temperatures. This cavitation erodes the delicate electroplated gold, rhodium, or chrome finishes on treatment probes. Microscopic pits form on the probe face, leaching metal ions (nickel, copper, chromium) directly onto the patient's skin, which can cause contact dermatitis and permanent device cosmetic damage. We eliminate high-frequency cavitation through high-vacuum centrifugal bubble extraction:
4. Sub-Micron Negative-Pressure Degassing: Uncured batches undergo mechanical shearing inside high-vacuum reactors drawn to an internal pressure of -0.096 MPa, stripping suspended micro-air pockets and dissolved atmospheric oxygen out of the matrix.
5. Cavitation-Free Fluid Homogeneity: The finished gel exhibits an internal micro-bubble count of zero under laser obscuration testing, forming a continuous, solid-liquid boundary against the probe.
6. Long-Term Metallurgical Protection: Under high-speed macro-microscopic monitoring during continuous 500 Hz, 40Vpp alternating electrical stress over 72 hours, our gel demonstrated zero bubble cavitation, zero electric arcing, and Grade 0 metallurgical pitting on plated probe faces, keeping luxury treatment devices unblemished and skin free from leached metallic contaminants.
Applications
At-Home Dual-Sphere Microcurrent Device Starter Bundling
Sourced in high container volumes by consumer beauty-tech device brands and Amazon top-sellers as the factory-bundled primary consumable inside retail device hardware boxes (dual-sphere toning rollers, microcurrent gua sha tools, mini facial sculpting devices); packaged in portable 50 ml or 100 ml soft-touch PE squeeze tubes with induction foil seals, serving as the required starter contact medium that ensures new device purchasers experience smooth probe glide without electrical stinging or post-care breakouts, reducing product return rates on e-commerce platforms while driving high-margin recurring bottle sales.
Medical Aesthetic Spas & Post-Operative Lymphatic Drainage Therapy
Deployed across dermatology clinics, medical spas, and plastic surgery recovery centers utilizing professional multi-channel microcurrent consoles and dual-pronged gold probes following facial liposuction, facelifts, or laser resurfacing; the isotonic, non-stinging mineral formulation allows practitioners to deliver gentle microcurrent drainage protocols across bruised, swollen, or sensitized facial tissues, accelerating interstitial fluid clearance and reducing post-procedural edema without irritating fragile skin incisions.
Bells Palsy & Facial Neuropathy Physical Rehabilitation Suites
Sourced by hospital physical rehabilitation departments and outpatient neurology clinics treating Bell's palsy, facial nerve decompression patients, and stroke survivors; clinicians apply the non-drying gel beneath active electrotherapy probe tips to stimulate atrophied mimetic muscles (orbicularis oculi, zygomaticus, buccinator) across 20-minute stimulation runs, maintaining low contact impedance without requiring messy reapplication during clinical therapy sessions.
OEM & Private Label
-
Container Options, Dispensing Closures & Custom Brand Packaging : We provide comprehensive contract manufacturing and formulation adjustments for private-label electrotherapy brands and clinical supply chains:
• Container Formats: Compact 50 ml and 100 ml soft-touch PE squeeze tubes (ideal for bundling inside retail device hardware boxes); standard 150 ml and 200 ml ergonomic cylindrical tubes with ribbed non-slip finger grips; professional 250 ml and 500 ml cylindrical HDPE bottles with lockable dispensing pumps; and heavy-duty 1-liter to 5-liter clinical cubitainers with integrated spigots for clinic refill operations.
• Dispensing Closure Types: Precision flip-top dispensing caps with orifice diameters from 2.0 mm to 3.5 mm (calibrated to dispense exact gel beads onto dual-sphere probes); push-pull directional spouts; and airless lotion pumps engineered to dispense viscous gels without product air-locking.
• Coloration & Functional Customization: Standard crystal-clear transparent hydrogel; optional subtle clinical blue tint (FD&C Blue #1) or soothing botanic green tint; and support for clean-label active functional compounding, including Multi-Molecular Hyaluronic Acid (5 kDa to 1.5 MDa), Plant-Derived Squalane Micro-Emulsions, Aloe Vera Leaf Juice Concentrates, and Centella Asiatica / Madecassoside calming fractions.
• Turnkey Packaging Customization: Multi-color offset and silk-screen tube printing, soft-touch matte varnishes, metallic hot-stamping, custom folding retail cartons, Amazon-compliant FNSKU barcodes, and serialized GS1/UDI tracking codes.
-
Two-Center Supply Chain Mechanics : High-purity deionized water generation, polymer synthesis, high-shear vacuum homogenization, and bulk chemical quality assurance execute natively inside our primary China facility (ISO 13485:2016 and FDA registered under 21 CFR 820). Automated tube blow-molding, cleanroom rotary filling, ultrasonic tail-sealing, retail kit boxing with localized device hardware, and palletized ocean container export route through our Vietnam manufacturing hub, shielding international B2B buyers from Section 301 tariffs and regional consumable import barriers.
Certifications
-
ISO 10993 Comprehensive Dermal Biocompatibility : Master production lots undergo testing in accredited independent GLP testing laboratories confirming strict compliance with ISO 10993-5 (In Vitro Cytotoxicity: Grade 0, non-cytotoxic), ISO 10993-10 (Skin Sensitization: 0% allergic response in guinea pig maximization assays), and ISO 10993-23 (Primary Dermal Irritation Index = 0.0, non-irritating). The formula is certified 100% natural rubber latex-free, phthalate-free, non-comedogenic, water-soluble, and non-sensitizing over prolonged daily clinical contact.
-
Probe Metallurgical Anti-Corrosion Testing : Evaluated in metallurgical testing laboratories under ASTM G48 protocols, confirming Grade 0 pitting and zero electroplating degradation across vacuum-metallized chromium, decorative nickel, 24K flash gold, and titanium treatment probes after 72 hours of continuous electrical exposure.
-
Microbiological Purity & Antimicrobial Preservation : Formulated in compliance with USP <51> Antimicrobial Effectiveness Testing, demonstrating rapid 28-day challenge reduction of bacteria, yeasts, and molds without relying on skin-sensitizing parabens or formaldehyde releasers. Certified compliant with USP <61>/<62> microbiological limits: Total Aerobic Microbial Count (TAMC) < 10 CFU/g, Total Yeast and Mold Count (TYMC) < 10 CFU/g, and verified total absence of Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, and Candida albicans.
-
MDSAP & ISO 13485 Manufacturing System Controls : Compounding suites, cleanroom bulk storage, and automated rotary bottling bays operate under certified ISO 13485:2016 and MDSAP regulatory frameworks (covering US FDA 21 CFR 820, Health Canada, TGA Australia). Unbroken electronic Device History Records (DHR) capture bulk deaeration vacuum levels, Brookfield rheological viscosity curves, potentiometric pH assays, electrical conductivity, and automated fill weights across every manufactured production lot.
Technical FAQ
Q: Why do dual-sphere metallic microcurrent rollers scrape and drag on facial skin when used with standard aloe vera gel or ultrasound couplant, and how does the hydrodynamic wedge network resolve this?
A: The mechanical dragging and skin-pulling occurring under dual-sphere rollers stems from concentrated line-contact shear mechanics interacting with low-yield fluids: The Physics of Dual-Sphere Roller Shear: Handheld microcurrent devices utilize two spherical metal probes (typically 15 mm to 25 mm in diameter) spaced closely together. When a user applies the device along the jawline or cheekbone: 1. The spherical curvature creates a narrow, focused line of contact with facial skin rather than a broad planar interface. 2. The manual upward lifting force generates normal pressures translating into localized shear stresses exceeding 150 Pa across a contact boundary less than 2 mm wide. 3. Standard cosmetic gels (such as 99% aloe vera gels) and medical ultrasound couplants are simple pseudoplastic fluids designed for static rest or broad-probe scanning. They have negligible yield stress (<15 Pa) and lack elastomeric extensional viscosity. 4. Under the focused traveling weight of the metal spheres, the generic gel is easily displaced and squeezed laterally away from the roller path. Within two lifting passes, the central track is wiped bare. 5. The bare metal of the spheres contacts the dry stratum corneum directly. Frictional drag spikes, causing the probe to chatter, catch, and pull the epidermis upward, stretching elastic tissue and causing immediate erythema and user discomfort. Our Hydrodynamic Wedge Engineering Solution: Gel Microcurrent eliminates probe chattering and skin drag through an engineered Bingham plastic rheological lattice: 1. Calibrated Yield Stress Core (>65 Pa): Compounding bio-fermented polyglutamate with high-purity cellulosics builds a structured 3D polymer lattice with a high yield stress threshold. The gel resists being displaced sideways under normal probe pressure. 2. The Hydrodynamic Wedge Mechanism: Under the kinetic traveling motion of the rolling metal sphere, the advancing curved profile draws the viscoelastic gel downward into the narrowing gap beneath the probe. The fluid generates a localized hydrodynamic lift pressure, creating an unbroken fluid wedge (thickness >50 um) that floats the metal probe above the skin. 3. Unbroken Fluid Lubrication: The spheres glide smoothly across facial contours without catching or tugging delicate skin, providing consistent electrical contact and a comfortable, frictionless lifting massage across 20-minute protocols.
Q: What is the fundamental difference in electrical conductivity design between microcurrent facial gel and body TENS electrode gel, and why can they not be interchanged?
A: The fundamental difference between facial microcurrent gel and body TENS gel lies in current amplitude compatibility, sensory nerve thresholds, and facial follicular safety: The Physics of Body TENS Conductive Gels: Transcutaneous Electrical Nerve Stimulation (TENS) applied to major muscle groups operates in the milliampere range (10 mA to 80 mA). At these high currents: 1. Body gels require high concentrations of inorganic electrolyte salts (typically 2.0% to 3.5% sodium chloride) to drive volume resistivity below 15 Ohm-cm (conductivity >10 mS/cm) to minimize thermal Joule dissipation under high amperage. 2. If applied to the face during microcurrent therapy, this massive concentration of mobile halide ions (Cl^-) creates severe hypertonic osmotic pressure across delicate facial skin, stripping moisture from basal cells and inducing acute burning erythema on skin sensitized by retinoids or chemical peels. 3. Furthermore, body TENS gels utilize synthetic, high-film-strength carbomers designed to resist sweat. On the face, these unabsorbable, non-water-soluble polymers dry inside facial pores, creating occlusive comedogenic plugs that cause severe post-treatment acne breakouts. The Physics of Dedicated Facial Microcurrent Gels: Facial microcurrent devices operate at sub-sensory micro-amperage (50 uA to 600 uA), which is 1,000 times lower than body TENS currents. At micro-ampere levels: 1. High-salinity low resistance is unnecessary; instead, electrical continuity requires stable, homogeneous charge dispersal without sensory nerve depolarization. 2. Gel Microcurrent is formulated with a non-ionic, organic mineral electrolyte complex that stabilizes electrical conductivity at an exact 0.8 to 1.4 mS/cm window (resistivity 700 to 1,200 Ohm-cm). 3. This calibrated conductivity allows sub-sensory pulse trains to cross the stratum corneum without triggering A-delta sensory pain fibers of the facial trigeminal nerve, eliminating the electric stinging, involuntary muscle twitches, and metallic oral tastes caused by mismatched gels. 4. Finally, the vehicle uses 100% water-soluble polysaccharides that rinse away in cool water in under 15 seconds with a verified comedogenicity rating of Grade 0, keeping facial pores clear and preventing breakouts.
Beauty hardware manufacturers, medical aesthetic spa directors, and skincare brand procurement managers can request official Certificates of Analysis (COA), 150 Pa hydrodynamic wedge tribology test records, ASTM G48 probe metallurgical anti-corrosion test logs, ISO 10993 biocompatibility testing dossiers, and unbranded evaluation sample packs (including 50 ml and 100 ml soft-touch squeeze tubes).
👉 [Request Gel Microcurrent Evaluation Sample Packs]
Hot Tags: gel microcurrent, China gel microcurrent manufacturers, suppliers, factory, microcurrent conductive gel, best microcurrent conductive gel, Conductive Gel for Facial Toner, microcurrent facial gel, Conductive Gel for Ultrasonic Cavitation, ultrasound conductive gel
Specifications
| No. | Item No | Volume | Package |
| 1 | TG-65ML | 65ml/2.3oz | 200pcs/carton, Carton dimession: 43cm*36cm*28cm, Gross weight: 14.5kgs |
| 2 | TG-90ML | 90ml/3.2oz | 160pcs/carton, Carton dimession: 43cm*36cm*28cm, Gross weight: 16kgs |
| 3 | TG-100ML | 100ml/3.5oz | 160pcs/carton, Carton dimession: 48cm*40cm*33cm, Gross weight: 17.5kgs |
| 4 | TG-150ML | 150ml/5.3oz | 160pcs/carton, Carton dimession: 48cm*40cm*33cm, Gross weight: 17kgs |
| 5 | TG-250ML | 250ml/8.9oz | 50pcs/carton, Carton dimession: 40cm*30cm*30cm Gross Weight:17kgs |







