OEM Electrode Jelly | High-Viscosity EEG/ECG Medium | TOP-RANK
B2B electrode jelly for prolonged clinical monitoring. Formulated with a high-density polyacrylic network to resist thermal liquefaction at 37C and maintain signal baselines.
Product Overview
This electrode jelly is a dense, non-flowing conductive medium engineered for specialized diagnostic hardware. Unlike standard liquid coupling gels that spread thinly across the epidermis, this paste-like matrix is formulated to hold its physical shape under mechanical stress and elevated body temperatures. It acts as both a primary electrical bridge and a structural filler for rigid hardware, such as EEG cup electrodes or heavy reusable ECG clamps. We compound this high-viscosity material in bulk vats for B2B clinical distributors and neurological equipment OEMs.
Key Features
-
Thermal Liquefaction Resistance
Standard conductive gels experience a severe drop in viscosity when exposed to the continuous 37C heat of human skin. Over a 12-hour EEG monitoring session, liquefied gel flows out from under the electrode, breaking the electrical connection and matting the patient's hair. This jelly matrix utilizes a heat-stable polyacrylic backbone. The polymer grid does not melt or collapse at biological temperatures, confining the conductive medium strictly to the original application footprint for up to 24 hours.
-
Heavy-Duty Volumetric Bridging
Rigid metal EEG cups and older reusable ECG hardware do not sit flush against the curving topography of the human skull or ribcage. A thin liquid gel cannot fill these massive geometric discrepancies, leaving empty air voids that block signal capture. The high resting viscosity of this jelly allows clinicians to build a thick, three-dimensional vertical pillar of conductive material. This physical volume bridges the structural gap between the skin and the recessed metal sensor, displacing all air and creating a massive, uninterrupted signal conduit.
-
Concentrated Chloride Suspension
Capturing neurological signals requires penetrating the inherent electrical resistance of the stratum corneum. To force the impedance down, the jelly is heavily loaded with chloride electrolytes. In a low-viscosity fluid, over-saturating the matrix with salts causes syneresis-a chemical failure where the water permanently separates from the polymer, leaving a useless liquid puddle. The ultra-dense cross-linking of this jelly acts as a mechanical cage, locking the high-concentration chlorides in a stable suspension without phase separation.
Applications
Long-Term EEG
Fills the cavity of gold or silver-chloride EEG cups to maintain micro-volt signal transfer through hair density over 24-hour periods.
Cardiac Stress Testing
Resists intense kinetic displacement and localized diaphoresis (sweating) during treadmill ECG protocols.
Defibrillation
Thick application layer prevents metal-to-skin arcing during high-joule energy discharges.
OEM & Private Label
-
Wide-Orifice Packaging : The 100,000+ cPs viscosity prevents this material from passing through standard 3mm gel nozzles. We package this jelly in wide-mouth 100g screw-top jars for spatula application, or heavy-duty PE tubes with oversized 8mm extrusion orifices.
-
Logistics Routing : The heavy-shear vacuum compounding operates inside our China facilities. Bulk vats are transferred to our automated filling lines, and final retail packaging and international palletization route through our Vietnam hub to optimize specific medical consumable tariffs.
Certifications
-
Systems: High-viscosity compounding and volumetric filling lines operate within audited ISO 13485:2016 frameworks.
-
Biocompatibility: Chemical matrices pass ISO 10993-5 (Cytotoxicity) endpoints to qualify for prolonged epidermal exposure.
FAQ
Q: Can this high-viscosity jelly be pumped through standard clinical wall-mounted dispensers?
A: No. The thixotropic threshold is too high. The internal spring and valve mechanisms of a standard liquid pump cannot generate enough negative pressure to draw the paste up the stem. It must be manually squeezed from a tube or scooped from a jar.
Q: Does the high chloride content damage ultrasound imaging probes?
B2B neurological hardware distributors can request 100g jar prototypes and high-temperature rheology reports.
👉 [Request Electrode Jelly Sample]
Hot Tags: electrode jelly, China electrode jelly manufacturers, suppliers, factory, Electrode Gel, gel for ecg, TENS Electrode Adhesive Gel, ekg gel, electro conductive gel, Electrode Contact Gel
Specifications
|
No. |
Item No |
Volume |
Package |
|
1 |
TG-65ML |
65ml/2.3oz |
200pcs/carton, Carton dimession: |
|
2 |
TG-90ML |
90ml/3.2oz |
160pcs/carton, Carton dimession: |
|
3 |
TG-100ML |
100ml/3.5oz |
160pcs/carton, Carton dimession: |
|
4 |
TG-150ML |
150ml/5.3oz |
160pcs/carton, Carton dimession: |
|
5 |
TG-250ML |
250ml/8.9oz |
50pcs/carton, Carton dimession: |