Custom Electrode Adhesive Gel

Custom Electrode Adhesive Gel
Details:
Materials : The formulation relies on a high-molecular-weight Carbomer or pHEMA lattice, neutralized to a specific rheology. We adjust the glycerol-to-water ratio to control the desiccation rate and adhesive "open time" according to the customer's clinical protocol.

Substrate Compatibility: The adhesive chemistry is titrated to ensure wetting on low-energy surfaces like carbon-silicone or medical-grade PET films. This prevents the "puddling" effect and ensures a continuous electrical path from the lead wire to the dermis.

ISO Standards: Produced in ISO 13485 cleanrooms. Formulations follow prudent regulatory phrasing regarding ISO 10993-5/10 biocompatibility, avoiding the unsubstantiated "100% biocompatible" claims common in low-end marketing.

MOQ:10,000 units for customized package.
Send Inquiry
Download
Description
Technical Parameters
 

Custom Electrode Adhesive Gel | High-Tack Conductive Paste | TOP-RANK

 

 

Custom-formulated adhesive gel for medical electrodes. Features adjustable viscosity (100k-200k cps) and calibrated tackiness. pH-buffered for ISO 10993 biocompatibility.

 

Product Overview

 

This custom adhesive gel is a high-viscosity, ionically conductive paste designed for applications where standard liquid gels fail due to migration or low tack. The gel functions as both a conductive bridge and a mechanical stabilizer, maintaining electrode placement during long-term monitoring or high-intensity stimulation. We provide B2B customization of the polymer matrix to match specific substrate surface energies.

 

Key Features

 

  • Tunable Viscosity Rheology

    Standard gels often "run" when exposed to 37C body heat. Our custom logic allows for the engineering of a shear-thinning profile where the gel stays rigid under gravity but spreads evenly under manual application pressure. This prevents the gel from leaking into hair follicles or clothing during 24-hour ambulatory monitoring.

     

  • Impedance Stability via Ionic Titration

    Lowering resistance usually involves high salt concentrations, which can cause skin irritation. We utilize a balanced electrolyte titration that achieves < 50 Ohm interface resistance while maintaining a skin-neutral pH. This preserves the signal-to-noise ratio in diagnostic applications without triggering Type IV allergic reactions.

     

  • Cohesive Integrity vs. Surface Tack 

    A common failure in adhesive gels is cohesive fracture, leaving residue on the skin upon removal. We calibrate the cross-linking density so that the internal molecular bond is always stronger than the surface adhesion. This ensures a clean, one-piece removal from both the electrode hardware and the patient's skin.

 

Applications

 

Long-term EEG/ECG

Adhesive medium for reusable metal cup electrodes in sleep labs.

 

Neonatal Monitoring

Low-peel force custom formulations for fragile infant skin.

 

Custom OEM Hardware

Conductive interface for proprietary wearable stimulators or diagnostic probes.

OEM & Private Label

 

  • Supply Chain Hubs: Bulk polymerization and chemical synthesis are executed in our China facility; final bottling, custom labeling, and global fulfillment are managed via our Vietnam hub to optimize tariff structures.

  • Packaging Specs: Available in 60ml travel tubes, 90ml,100ml,150ml,250ml squeeze bottles with flip-tops

 

Certifications

 

Regulatory: FDA 510(k), CE (MDR), UKCA.

Systems: ISO 13485:2016 and MDSAP compliant.

Batch QC: Every lot is tested for viscosity (Brookfield), pH stability, and microbial bioburden (< 10 CFU/g).

 

FAQ

Q: Why does the gel's tackiness decrease in low-humidity environments?

A: Tackiness is dependent on the hydration level of the polymer matrix. In < 20% RH, water molecules migrate out of the gel, causing the polymer chains to contract and lose surface wetting capability. We can adjust the humectant (Propylene Glycol/Glycerol) ratio to mitigate this effect for specific climates.

Q: Is this gel compatible with silver/silver-chloride (Ag/AgCl) sensors?

A: Yes. The electrolyte balance is titrated to be non-reactive with Ag/AgCl surfaces, preventing the chemical reduction that causes signal drift and baseline instability in diagnostic devices.

CTA

 

B2B procurement teams can request batch-specific COAs and rheological stability reports for engineering review.

👉 [Request Custom Gel Samples]

 

Hot Tags: custom electrode adhesive gel, China custom electrode adhesive gel manufacturers, suppliers, factory, TENS electrode gel, Electro Gel for Electro Caps, Electrotherapy Conductive Gel, electrode gel for TENS unit, Conductive Gel, Electrode Gel

Products Description

 

No. Item No Volume Package
1 TG-65ML 65ml/2.3oz 200pcs/carton, Carton dimession:
43cm*36cm*28cm, Gross weight: 14.5kgs
2 TG-90ML 90ml/3.2oz 160pcs/carton, Carton dimession:
43cm*36cm*28cm, Gross weight: 16kgs
3 TG-100ML 100ml/3.5oz 160pcs/carton, Carton dimession:
48cm*40cm*33cm, Gross weight: 17.5kgs
4 TG-150ML 150ml/5.3oz 160pcs/carton, Carton dimession:
48cm*40cm*33cm, Gross weight: 17kgs
5 TG-250ML 250ml/8.9oz 50pcs/carton, Carton dimession:
40cm*30cm*30cm Gross Weight:17kgs