Natural Look Conductive Gel

Natural Look Conductive Gel
Details:
Achieve a natural beauty boost with our premium Natural Look Conductive Gel. Specially formulated to optimize conductivity, this gel enhances the effectiveness of beauty treatments while preserving your natural look.

Natural Look Conductive Gel functions as a clean-finish acoustic and electro-conductive coupling medium formulated for consumer and clinical facial toning devices, including sub-sensory microcurrent applicators (100 uA to 500 uA), galvanic iontophoresis rollers, ultrasonic skin spatulas, and low-thermal radiofrequency (RF) wands.

The industrial synthesis and filling of clean-finish Natural Look Conductive Gel take place in ISO 13485-certified Class 8 cleanrooms across closed-loop stainless steel processing suites equipped with sub-micron vacuum homogenizers, nitrogen-blanketed mixing tanks, and automated rotary tube-filling lines.
Send Inquiry
Download
Description
Technical Parameters
 

OEM Natural Look Conductive Gel | Clean-Finish Coupling Medium | TOP-RANK

 

 

B2B contract manufacturing of clean-finish Natural Look Conductive Gel for facial electrotherapy devices. Formulated for zero-rinse matte absorption, zero probe plating corrosion, botanical thermal stability under 42C, USP microbiological compliance, and turnkey OEM packaging.

 

Product Overview

 

Natural Look Conductive Gel functions as a clean-finish acoustic and electro-conductive coupling medium formulated for consumer and clinical facial toning devices, including sub-sensory microcurrent applicators (100 uA to 500 uA), galvanic iontophoresis rollers, ultrasonic skin spatulas, and low-thermal radiofrequency (RF) wands. Applied across the face and neck, the gel eliminates air voids between metallic probe faces and the stratum corneum, stabilizing electrical transfer while delivering frictionless probe glide. Unlike heavy industrial coupling media designed strictly for post-treatment wash-off, this formulation acts as a hybrid coupling-and-absorption vehicle: it provides an open slip window during active hardware passes, then absorbs or wipes clean with zero shiny residue, leaving a dry, non-tacky matte finish that does not interfere with daily skincare or makeup application.

Standard clinical ultrasound and conductive gels create three practical and chemical failures when applied to daily consumer facial hardware:

  • Occlusive Polymer Residue and Cosmetic Incompatibility ("Pilling"): Conventional coupling gels rely on high-molecular-weight synthetic carbomers neutralised with heavy salts. When dried or partially wiped off, the polymer backbone collapses into an insoluble, sticky plastic film across the face. Applying subsequent moisturizers, sunscreens, or foundation causes the dehydrated polymer residue to ball up into rubbery flakes (cosmetic pilling), clogging pores and leaving a greasy, unnatural shine that forces users to wash their face aggressively with surfactants.
  • Electrolytic Pitting Corrosion on Decorative Probe Electroplating: Home beauty devices often feature aesthetic metallic coatings, including vacuum-metallized chrome, electroplated bright nickel, or flash-gold finishes on plastic ABS housings. Standard conductive gels contain up to 2.0% inorganic chloride salts to boost conductivity. Under continuous electrical current, these chloride ions initiate pitting corrosion along microscopic plating defects, blistering the metallic coating and depositing greenish-black metal salts onto the user's skin within weeks.
  • Thermal Photo-Oxidation and Discoloration of Plant Actives: Formulations blending natural plant extracts (such as Aloe Vera, Chamomile, or Vitamin E) with basic gel bases frequently experience degradation during electro-thermal treatments. Friction and RF heat (reaching 38C to 42C at the probe face) break down unstable botanical extracts. The gel turns yellowish-brown inside the tube, develops rancid organic odors, and stains light-colored device plastics.

This clean-finish conductive gel platform resolves these operating drawbacks through an engineered cosmetic-medical matrix: a low-residue polysaccharide-acrylic cross-polymer hybrid that transitions from a fluid glide film to an invisible matte finish upon light wiping; a non-corrosive, salt-free colloidal conduction phase that maintains microcurrent conductivity between 0.8 and 2.2 mS/cm without attacking decorative probe electroplating; and a cold-process vacuum homogenization protocol that encapsulates natural phytosterols, stabilizing them against thermal breakdown up to 45C. We contract-manufacture private-label squeeze tubes, airless pump dispensers, and clinic-size containers for beauty tech OEMs, aesthetic device distributors, and clean-label skincare brands globally.

 

Technical & Engineering Description

 

The industrial synthesis and filling of clean-finish Natural Look Conductive Gel take place in ISO 13485-certified Class 8 cleanrooms across closed-loop stainless steel processing suites equipped with sub-micron vacuum homogenizers, nitrogen-blanketed mixing tanks, and automated rotary tube-filling lines. Compounding executes through five coordinated processing stages:

  • Stage 1: Multi-Pass Deionized Water Polishing & Organic Buffer Hydration: The continuous phase uses pharmaceutical-grade purified water polished through dual-pass reverse osmosis (RO) and continuous electrodeionization (EDI), driving baseline electrical conductivity below 0.1 uS/cm. The deionized water is transferred into 316L stainless steel jacketed reactors and heated to 75C to 80C. Pharmaceutical-grade bio-fermented sodium hyaluronate and an organic carboxylate buffer are metered into the bulk under low-shear marine propeller agitation, establishing an electrolyte baseline of 0.8 to 2.2 mS/cm without introducing corrosive chloride ions.
  • Stage 2: Hybrid Polysaccharide-Polymer Dispersion: A balanced gelling matrix-combining high-purity de-hydroxylated xanthan gum (derived from non-GMO Xanthomonas fermentation) and a cosmetic-grade hydrophobically modified cross-linked acrylic copolymer-is injected into the liquid vortex using dry-powder vacuum induction at 2,800 RPM. The combination of natural branched polysaccharides and acrylic chains prevents macro-molecular bundling. The dispersion hydrates under continuous planetary sweeps for 45 minutes, creating a smooth suspension free of unhydrated polymer cores or fisheyes.
  • Stage 3: Sub-Micron Vacuum Homogenization & Deaeration: The slurry is neutralized to a physiological pH of 5.50 (+/- 0.30) using an ultra-pure alkaline buffering agent, triggering the polymer chains to untangle into an elastic 3D grid. The vessel is sealed and drawn down to an ultra-high vacuum level of -0.095 MPa while the bottom-mounted stator-rotor homogenizer operates at 3,000 RPM for 30 minutes. This evacuates dissolved oxygen and micro-air pockets, yielding a crystal-clear gel matrix and eliminating micro-cavitation voids that can cause electrical breakdown during microcurrent conduction.
  • Stage 4: Cold-Process Botanical Encapsulation (<35C): The jacketed vessel circulates chilled water to cool the bulk matrix to 32C. An active botanical emulsion-combining cold-pressed Aloe Barbadensis leaf extract, German Chamomile (Chamomilla Recutita) flower distillate, and d-alpha-tocopheryl acetate (Vitamin E)-is pre-blended in a satellite vessel with bio-fermented 1,3-propanediol. This pre-mix is metered into the main tank under low-shear helical ribbon mixing. Cold blending prevents thermal degradation of natural phytosterols and polyphenols, keeping the final formulation chemically stable against oxidation up to 45C.
  • Stage 5: Sanitary Micro-Filtration & High-Speed Packaging: The finished gel passes through a 10 um sanitary stainless steel cartridge filter directly to automated rotary filling stations. Multi-layer PE tubes (or airless pump bottles with EVOH oxygen barriers) are loaded, bottom-filled with zero product tailing via volumetric servo ceramic pistons, and ultrasonically sealed with lot and expiration stamping. Every batch undergoes inline visual check-weighing, fill-level confirmation, and optical seal testing. The baseline private-label contract manufacturing MOQ is 50,000 units.

 

Key Features

 

  1. Low-Chloride Organic Electrolyte Buffer (Preserving Electrical Continuity While Neutralizing Probe Plating Pitting Corrosion) 

    A prevalent point of mechanical and cosmetic failure in consumer electrotherapy devices is corrosion on the handpiece treatment surface. Handheld microcurrent and galvanic facial devices utilize metal contact electrodes electroplated with thin layers (typically 0.2 um to 0.5 um) of bright chromium, decorative nickel, or flash gold over injection-molded ABS or zinc alloy substrates. When generic medical conductive gels-compounded with 1.5% to 3.0% inorganic sodium chloride or potassium chloride-are applied over these plated surfaces:

    1. Chloride Ion Attack: The small ionic radius of dissociated chloride ions allows them to migrate through microscopic pinholes and micro-cracks in the electroplated barrier.

    2. Galvanic Cell Generation: Under positive and negative electrical current cycles, chloride ions break down the passive oxide layer on the metal plating. A galvanic corrosion cell forms between the surface metal and the underlying substrate.

    3. Delamination and Metal Leaching: The electroplated layer blisters, micro-flakes off the plastic housing, and deposits greenish-black metal oxide tarnish on the treatment probe and the user's face. Our formulation eliminates plating corrosion through a chloride-free organic electrolyte balancing system:

    4. High-Molecular Organic Carboxylates: Inorganic salts are completely replaced with bio-fermented sodium hyaluronate and organic carboxylic acid buffers. The larger molecular radii of these organic ions prevent them from penetrating micro-crevices in metallic electroplating.

    5. Controlled Electrical Mobility: The organic electrolyte system stabilizes bulk electrical conductivity between 0.8 and 2.2 mS/cm. This conductivity level is sufficient to lower the cutaneous contact impedance below 1,500 Ohms-allowing microcurrent waveforms to pass without distortion-while remaining electrochemically inert to metallic plating. In standardized electrochemical corrosion evaluations (ASTM G48 with continuous 72-hour anodic polarization under 20V electrical bias), treatment probes coated with this gel showed zero surface pitting, zero plating blisters, and zero discoloration across chromium, nickel, and gold contact surfaces. 

     

  2. Post-Treatment Phase-Inversion Dermal Absorption (Dry-Touch Matte Finish Eliminating Cosmetic Pilling and Post-Therapy Washing) 

    Standard facial conductive gels are engineered with high concentrations of crosslinked carbomers and cellulose polymers that cannot absorb into the human skin barrier. Following an electrotherapy session, the user must aggressively wipe or wash the gel off:

    1. Wipe-Off Breakdown: If partially wiped away with tissues, residual polymer lines remain inside facial creases. As the water phase evaporates, the long polymer chains collapse into a crystalline, sticky plastic film across the face.

    2. Cosmetic Pilling: When the user applies daily skincare products (creams, sunscreens) or silicone-based cosmetic foundations over this dried film, the shear friction of application rolls the insoluble polymer residue into visible white rubbery balls ("pilling").

    3. Barrier Disruption from Washing: If the user washes the face with surfactant cleansers immediately after thermal or microcurrent stimulation, the warm, permeable epidermal barrier is stripped of natural ceramides and intercellular lipids, causing acute post-treatment redness and flaking. We eliminate polymer residue and cosmetic pilling through a hybrid polysaccharide-copolymer phase-inversion architecture:

    4. Natural-Synthetic Polymer Balance: The formulation blends de-hydroxylated bio-fermented xanthan gum with a lightweight cosmetic acrylate cross-polymer. During device operation, the polymer chains remain tangled in a high-lubricity shear-thinning fluid state.

    5. Phase Inversion Under Light Rubbing: Following the device pass, light manual patting breaks the mechanical water-cage grid. The polymer lattice collapses into a low-viscosity micro-emulsion. Free water and hydrophilic humectants (1,3-propanediol, low-molecular hyaluronic acid) penetrate into the stratum corneum, hydrating the skin.

    6. Non-Reflective Matte Finish: The remaining surface fraction dries into a microscopic, non-continuous breathable veil with zero surface shine and zero adhesive tack. In consumer application trials involving subsequent liquid foundation and sunscreen application, the absorbed gel layer showed zero cosmetic pilling (pilling score = 0), zero skin stickiness, and a non-shiny, matte finish that eliminates the need for post-treatment facial washing. 

     

  3. Cold-Encapsulated Botanical Thermal Shield (Stabilizing Aloe, Chamomile, and Vitamin E Actives Against 42C Hardware Heat Degradation) 

    Clean-label cosmetic positioning requires the integration of soothing botanical extracts to counteract treatment-induced erythema. However, blending natural actives into conductive media exposes them to destabilizing thermal conditions. During multi-polar RF, ultrasonic heating, or extended galvanic sessions, localized temperatures at the treatment probe interface reach 38C to 42C. Conventional hot-process compounding causes three chemical degradations:

    1. Anthraquinone Browning: Phytosterols and polysaccharides in Aloe Barbadensis degrade under heat, cross-reacting with dissolved oxygen to turn the gel brown (Delta E > 4.5).

    2. Flavonoid Inactivation: Anti-inflammatory flavonoids in German Chamomile (apigenin, bisabolol) undergo thermal oxidation, losing over 60% of their soothing bioactivity.

    3. Tocopherol Cleavage and Odor Generation: Vitamin E (tocopheryl acetate) suffers hydrolysis under elevated temperatures and light exposure, producing pungent rancid fatty-acid odors and staining device plastic shells. We preserve active botanical integrity through a cold-process vacuum micro-emulsification protocol:

    4. Satellite Pre-Solubilization: Cold-pressed aloe polysaccharides, bisabolol-rich chamomile fractions, and tocopheryl acetate are pre-homogenized in a separate satellite vessel with bio-fermented 1,3-propanediol at 25C, shielding the botanical structures from heat.

    5. Low-Temperature Sub-Surface Metering: The active botanical premix is injected into the main deaerated gel matrix only after the batch has cooled below 32C under vacuum. The branched multi-molecular polymer network acts as a steric shield, encapsulating the fragile phytosterols within protective hydration cages. In thermal stability testing (maintaining continuous 45C exposure for 72 hours to simulate repeated thermal beauty device passes), the formulation demonstrated a spectrophotometric color shift Delta E < 1.2 (no visible browning), zero rancid odor formation, and active retention of natural flavonoids exceeding 92%.

 

Applications

 

At-Home Microcurrent & EMS Facial Sculpting Device Hardware Bundling

Sourced in high volume by consumer beauty tech hardware brands as the factory-bundled primary contact medium included inside retail gift boxes (microcurrent rollers, EMS facial contouring wands, ultrasonic scrapers); packaged in 100 ml or 150 ml soft-touch matte squeeze tubes with induction foil seals, serving as the required starter consumable that drives recurring monthly replenishment orders on e-commerce platforms without causing makeup pilling complaints.

 

Medical Aesthetic Clinics & Post-Extraction Dermal Calming Protocols

Deployed across professional aesthetic suites and dermatology medspas for gentle ultrasound nutrient infusion, post-laser microcurrent lymphatic drainage, and cold-hammer soothing protocols following chemical peels or pore extractions; packaged in 200 ml hygienic airless pump bottles or 1000 ml clinic refill containers, allowing practitioners to complete calming device treatments without using abrasive wet towels to scrub sensitized skin.

 

Galvanic Iontophoresis & Clean-Beauty Transdermal Nutrient Delivery

Utilized by clinical aesthetic operators and skincare brands pairing negative/positive galvanic rollers with transdermal active infusion; the salt-free, pH 5.5 buffered formulation provides low electrical resistance without dermal stinging, leaving an invisible matte finish that allows patients to apply sunscreen and makeup immediately for daytime work routines.

OEM & Private Label

 

  • Viscosity Tuning, Botanical Enrichment & Custom Packaging Configurations : We provide comprehensive contract manufacturing and formulation customization for global beauty hardware and skincare brands:

    • Custom Flow Tiers: Standard Matte Glide (50,000 cP for rapid microcurrent roller gliding); High-Cushion Toning (65,000 cP for lifting wands requiring elevated skin buffering); or Ultra-Light Serum-Gel (35,000 cP for ultrasonic facial spatulas).

    • Active Plant Enrichment: Support customizable compounding of clean-label functional extracts, including Organic Aloe Barbadensis Leaf Juice (hydration and cooling), German Chamomile Extract (anti-redness soothing), Centella Asiatica / Madecassoside (barrier repair), and High/Low Molecular Hyaluronic Acid (transdermal plumping).

    • Primary Packaging Options: Squeeze tubes from 50 ml to 200 ml (multi-layer PE, post-consumer recycled PCR, or aluminum barrier laminates with soft-touch matte coating, flip-caps, or metallic screw closures); luxury 100 ml to 200 ml airless pump dispensers; and 1-liter to 5-liter clinic back-bar refill jugs. Packaging options include multi-color silk-screen printing, metallic hot-stamping, matte soft-touch varnish, serialized GS1/UDI barcodes, and FSC-certified paper retail cartons. 

     

  • Two-Center Supply Chain Mechanics : High-purity bulk chemical synthesis, sub-micron vacuum homogenization, cold-process botanical compounding, automated cleanroom tube filling, and in-process analytical quality testing execute natively inside our primary China facility (ISO 13485:2016 and FDA registered). Final assembly, secondary retail kit packaging with localized device accessories, cleanroom carton sealing, and direct container logistics can be routed through our Vietnam manufacturing hub, shielding international B2B buyers from Section 301 tariffs and regional medical consumable import barriers.

 

Certifications

 

  • ISO 10993 Dermal Biocompatibility Testing : Master production lots undergo testing in accredited independent GLP laboratories confirming strict compliance with ISO 10993-5 (In Vitro Cytotoxicity: Grade 0 non-cytotoxic), ISO 10993-10 (Skin Sensitization: 0% allergic response in guinea pig maximization assays), and ISO 10993-23 (Primary Dermal Irritation Index = 0.0, non-irritating). The formula is certified 100% free of natural rubber latex, parabens, phthalates, mineral oil, synthetic fragrances, and artificial dyes. 

     

  • Probe Metallurgical Anti-Corrosion Testing : Evaluated in metallurgical testing laboratories under ASTM G48 protocols, confirming Grade 0 pitting and zero electroplating degradation across vacuum-metallized chromium, decorative nickel, 24K flash gold, and titanium treatment probes after 72 hours of continuous anodic-biased current exposure. 

     

  • Microbiological Purity & Preservative Efficacy : Formulated in compliance with USP <51> Antimicrobial Effectiveness Testing, demonstrating rapid 28-day challenge reduction of bacteria, yeasts, and molds without relying on aggressive sensitizing biocides. Certified compliant with USP <61>/<62> microbiological limits: Total Aerobic Microbial Count (TAMC) < 10 CFU/g, Total Yeast and Mold Count (TYMC) < 10 CFU/g, and verified total absence of Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, and Candida albicans. 

     

  • MDSAP & ISO 13485 Manufacturing System Controls : Synthesis reactors, cleanroom storage bays, and automated filling lines operate under certified ISO 13485:2016 and MDSAP regulatory frameworks (covering US FDA 21 CFR 820, Health Canada, TGA Australia). Unbroken electronic Device History Records (DHR) capture bulk deaeration vacuum levels, rheological viscosity curves, pH potentiometric assays, and fill-weight data across every manufactured lot for full traceability.

 

Technical FAQ

Q: Why do conventional conductive gels leave a sticky film that causes cosmetic pilling under sunscreen and foundation, and how does the phase-inversion matrix eliminate this?

A: Cosmetic pilling following conductive gel application is caused by the mechanical breakdown of dehydrated, high-molecular-weight synthetic polymers under frictional shear: The Pilling Mechanism of Standard Gels: Generic medical coupling media rely on high-molecular-weight homopolymer carbomers (molecular weights exceeding 1,000,000 Daltons) crosslinked into an inflexible 3D lattice and neutralized with inorganic salts. When applied to facial skin and wiped with a tissue post-treatment: • A thin liquid film remains trapped in microscopic skin creases and pores. • As the water phase evaporates, the linear polymer chains collapse and form irreversible crystalline hydrogen bonds with one another. •​​​​​​​ This forms an insoluble, cohesive plastic membrane that clings tightly to the outer stratum corneum. When the user subsequently applies a sunscreen, facial oil, or liquid foundation containing emulsifiers and volatile silicones, the physical shear of rubbing rolls this non-soluble polymer film off the skin. The dried polymer agglomerates into visible, rubbery flakes (cosmetic pilling). Furthermore, the collapsed polymer creates a shiny, unnatural reflection that accentuates facial pores. Our Phase-Inversion Polymer Architecture: We eliminate cosmetic pilling and sticky residue through a hybrid polymer formulation that undergoes phase inversion under manual shearing: •​​​​​​​ Natural-Synthetic Polymer Hybrid: The gel matrix combines de-hydroxylated xanthan gum (branched natural polysaccharide) with an optimized cosmetic-grade acrylic cross-polymer. The two polymer systems interpenetrate without forming rigid, continuous crystalline plates upon drying. •​​​​​​​ Shear-Induced Phase Inversion: During hardware movement, the polymer matrix maintains high lubricity and water retention. Once treatment ends, gentle fingertip patting breaks the internal water-cage bonds. The gel undergoes a structural inversion into a low-viscosity micro-fluid. •​​​​​​​ Dermal Absorption and Matte Veil: The volatile fluid fraction and hydrophilic humectants (1,3-propanediol, low-molecular hyaluronic acid) absorb directly into epidermal micro-crevices, plumping the stratum corneum. The remaining polymer fraction dries as an ultra-thin, non-continuous breathable veil. In standardized cosmetic compatibility trials, applying broad-spectrum SPF 50 sunscreen and liquid silicone foundation over the absorbed gel layer resulted in a pilling score of 0 (zero flaking), zero surface stickiness, and a non-reflective matte finish that eliminates the need for post-treatment washing.

Q: How does the salt-free organic electrolyte system achieve low-impedance microcurrent conduction without causing pitting corrosion on chrome or gold-plated device probes?​​​​​​​

A: Electrochemical corrosion on beauty device probes is driven by halide ion attack interacting with metallic electroplating during continuous electrical current passage: The Plating Corrosion Problem: Personal microcurrent, galvanic, and radiofrequency devices feature handpiece treatment heads manufactured from injection-molded ABS plastic or zinc alloys coated with decorative electroplated layers (such as 0.2 um to 0.4 um of bright chromium, decorative nickel, or flash gold). Standard conductive gels add 1.5% to 3.0% inorganic sodium chloride (NaCl) to lower electrical resistance. When an electrical potential (typically 15V to 40V) passes between the probe and the skin in the presence of these salts: •​​​​​​​ The small ionic radius of dissolved chloride ions (Cl-) allows them to migrate into micro-pores and micro-fractures in the electroplated barrier layer. •​​​​​​​ Driven by the electric field, chloride ions displace oxygen in the passive protective oxide film on the metal surface. •​​​​​​​ Once the protective film is broken, an electrochemical pitting cell forms between the surface metal and the underlying substrate metal. •​​​​​​​ The plating blisters, flakes off, and dissolves, generating dark greenish-black metal oxides that tarnish the probe face and transfer onto the patient's skin. Over time, the rough, corroded probe scratches the epidermis and interrupts electrical conduction. Our Non-Halide Organic Buffer Architecture: We eliminate plating corrosion by replacing inorganic salts with an organic carboxylate conduction network: •​​​​​​​ Zero Halide Salts: The formulation contains 0.0% inorganic chlorides, fluorides, or bromides, completely removing the chemical catalysts required for pitting corrosion. •​​​​​​​ High-Molecular Ionic Carriers: Electrical charge transfer is mediated by pharmaceutical-grade bio-fermented sodium hyaluronate and an organic carboxylate buffer pair. The large molecular dimensions of these organic ions prevent them from migrating through microscopic defects in electroplated metal coatings. •​​​​​​​ Targeted Electrical Conduction: The organic electrolyte system stabilizes bulk electrical conductivity within a controlled band of 0.8 to 2.2 mS/cm. This conductivity reduces the skin-probe contact resistance below 1,500 Ohms, enabling 100 uA to 500 uA microcurrent pulses to enter tissue without voltage drop, while remaining electrochemically inert to metallic plating. In standardized electrochemical corrosion trials (ASTM G48 with continuous 20V anodic polarization for 72 hours), treatment probes exposed to this gel showed Grade 0 pitting across chromium, decorative nickel, 24K gold, and surgical-grade 316 stainless steel, ensuring hardware preservation across hundreds of treatment cycles. 

 

 

Beauty device hardware manufacturers, clinical aesthetic networks, and clean-skincare brand directors can request official Certificates of Analysis (COA), ASTM G48 probe metallurgical anti-corrosion test reports, post-treatment cosmetic pilling evaluation records, ISO 10993 biocompatibility testing dossiers, and unbranded evaluation sample packs (including 100 ml soft tubes and 200 ml airless pump dispensers).

👉 [Request Natural Look Conductive Gel Evaluation Packs]

 

Hot Tags: natural look conductive gel, China natural look conductive gel manufacturers, suppliers, factory, microcurrent conductive gel, ultrasound conductive gel, cavitation conductive gel, best conductive gel for face, best microcurrent conductive gel, best conductive gel for cavitation

Specifications

 

No.

Item No

Volume

Package

1

TG-65ML

65ml/2.3oz

200pcs/carton, Carton dimession:
43cm*36cm*28cm, Gross weight: 14.5kgs

2

TG-90ML

90ml/3.2oz

160pcs/carton, Carton dimession:
43cm*36cm*28cm, Gross weight: 16kgs

3

TG-100ML

100ml/3.5oz

160pcs/carton, Carton dimession:
48cm*40cm*33cm, Gross weight: 17.5kgs

4

TG-150ML

150ml/5.3oz

160pcs/carton, Carton dimession:
48cm*40cm*33cm, Gross weight: 17kgs

5

TG-250ML

250ml/8.9oz

50pcs/carton, Carton dimession:
40cm*30cm*30cm Gross Weight:17kgs

Send Inquiry